» Articles » PMID: 3664626

Quantitative Analysis of Coronary Arteriograms by Microprocessor Cinevideodensitometry

Overview
Date 1987 Sep 1
PMID 3664626
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A rapid microprocessor technique for measuring the cross-sectional area, diameter, and relative percentage stenosis of coronary atherosclerotic lesions by cinevideodensitometric analysis was developed and validated. Video images of projected 35-mm coronary arteriographic cine frames were analyzed from cinevideodensitometric profile curves recorded for the catheter shaft, normal artery, and stenotic segment. In radiographic phantom studies of calibrated, contrast-filled, plexiglass cylinders, cinevideodensitometric measurements correlated linearly with percentage relative stenosis (r = 0.98; SEE = 4.1%), diameter (r = 0.99; SEE = 0.12 mm), and cross-sectional area (r = 0.99; SEE = 0.32 mm2). In postmortem studies of two patients dying after coronary arteriography, cross-sectional areas of arterial segments measured by cinevideodensitometry correlated well (r = 0.99; SEE = 0.71 mm) with areas of acrylic resin casts of the coronary arteries. Intraobserver variability (r = 0.99; SEE = 2.6%) and interobserver variability (r = 0.96; SEE = 5.3%) of cinevideodensitometric measurements of coronary arteriograms were low. Additionally, percentage relative stenosis measured in the right anterior oblique projection correlated well with measurements in the left anterior oblique projection (r = 0.98; SEE = 0.11 mm2) of patients with eccentric stenotic lesions. Lastly, cinevideodensitometric measurements were significantly (p less than 0.05) more reproducible than caliper measurements. This inexpensive dedicated microprocessor system provides rapid cinevideodensitometric measurements of coronary arterial dimensions, without requiring manual tracing of arterial segments or the major expense of a main-frame computer system.

Citing Articles

The impact of vessel orientation in space on densitometric measurements of cross sectional areas of coronary arteries.

Doriot P, Dorsaz P, Dorsaz L, Chatelain P, RUTISHAUSER W Int J Card Imaging. 1996; 12(4):289-97.

PMID: 8993991 DOI: 10.1007/BF01797742.


Pravastatin reduces restenosis after coronary angioplasty of high grade stenotic lesions: results of SHIPS (SHIga Pravastatin Study).

Nakamura Y, Yamaoka O, Uchida K, Morigami N, Sugimoto Y, Fujita T Cardiovasc Drugs Ther. 1996; 10(4):475-83.

PMID: 8924063 DOI: 10.1007/BF00051114.


Failure of epoprostenol (prostacyclin, PGI2) to inhibit platelet aggregation and to prevent restenosis after coronary angioplasty: results of a randomised placebo controlled trial.

Gershlick A, Spriggins D, Davies S, Syndercombe Court Y, Timmins J, Timmis A Br Heart J. 1994; 71(1):7-15.

PMID: 8297699 PMC: 483601. DOI: 10.1136/hrt.71.1.7.


Limitation of detection and evaluation of coronary arterial stenosis by densitometry.

Sugahara T, Kimura K, Yanagihara Y, Sugimoto N, Azumi T Int J Card Imaging. 1994; 10(1):35-43.

PMID: 8021529 DOI: 10.1007/BF01151579.


An objective computer system for the quantification of artery stenoses.

Wankling P, Perry R, Seth A, Hunt A, Escaned X, NEWELL J Int J Card Imaging. 1990; 5(2-3):85-92.

PMID: 2230300 DOI: 10.1007/BF01833977.