» Articles » PMID: 22127999

Feasibility, Reproducibility, and Reliability for the T*2 Iron Evaluation at 3 T in Comparison with 1.5 T

Abstract

This study aimed to determine the feasibility, reproducibility, and reliability of the multiecho T*(2) Magnetic resonance imaging technique at 3 T for myocardial and liver iron burden quantification and the relationship between T*(2) values at 3 and 1.5 T. Thirty-eight transfusion-dependent patients and 20 healthy subjects were studied. Cardiac segmental and global T*(2) values were calculated after developing a correction map to compensate the artifactual T*(2) variations. The hepatic T*(2) value was determined over a region of interest. The intraoperator and interoperator reproducibility for T*(2) measurements at 3 T was good. A linear relationship was found between patients' R *2 (1000/T*(2) ) values at 3 and 1.5 T. Segmental correction factors were significantly higher at 3 T. A conversion formula returning T*(2) values at 1.5 T from values at 3 T was proposed. A good diagnostic reliability for T*(2) assessment at 3 T was demonstrated. Lower limits of normal for 3 T T*(2) values were 23.3 ms, 21.1 ms, and 11.7 ms, for the global heart, mid-ventricular septum, and liver, respectively. In conclusion, T*(2) quantification of iron burden in the mid-ventricular septum, global heart, and no heavy-moderate livers resulted to be feasible, reproducible, and reliable at 3 T. Segmental heart T*(2) analysis at 3 T may be challenging due to significantly higher susceptibility artifacts.

Citing Articles

Medical Radiology: Current Progress.

Pepe A, Crimi F, Vernuccio F, Cabrelle G, Lupi A, Zanon C Diagnostics (Basel). 2023; 13(14).

PMID: 37510183 PMC: 10378672. DOI: 10.3390/diagnostics13142439.


Association of myocardial iron deficiency based on T2* CMR with the risk of mild left ventricular dysfunction in HIV-1-infected patients.

Yan C, Li R, Zhang J, Zhang L, Yang M, Zhang Q Front Cardiovasc Med. 2023; 10:1132893.

PMID: 37123480 PMC: 10130653. DOI: 10.3389/fcvm.2023.1132893.


Comparison of liver iron concentration calculated from R2* at 1.5 T and 3 T.

Pickles E, Kumar S, Brady M, Telford A, Pavlides M, Bulte D Abdom Radiol (NY). 2022; 48(3):865-873.

PMID: 36520162 PMC: 9941222. DOI: 10.1007/s00261-022-03762-4.


Myocardial T2* Imaging at 3T and 1.5T: A Pilot Study with Phantom and Normal Myocardium.

Chang S, Park J, Yang Y, Beck K, Kim P, Choi B J Cardiovasc Dev Dis. 2022; 9(8).

PMID: 36005435 PMC: 9410052. DOI: 10.3390/jcdd9080271.


T1 and T2∗ relaxation time in the parcellated myocardium of healthy Taiwanese participants: A single center study.

Tsai C, Ng S, Chen Y, Juan Y, Wang C, Lin G Biomed J. 2022; 44(6 Suppl 1):S132-S143.

PMID: 35735082 PMC: 9039095. DOI: 10.1016/j.bj.2020.08.013.