» Articles » PMID: 22110600

Probing the Limits of Aptamer Affinity with a Microfluidic SELEX Platform

Overview
Journal PLoS One
Date 2011 Nov 24
PMID 22110600
Citations 40
Authors
Affiliations
Soon will be listed here.
Abstract

Nucleic acid-based aptamers offer many potential advantages relative to antibodies and other protein-based affinity reagents, including facile chemical synthesis, reversible folding, improved thermal stability and lower cost. However, their selection requires significant time and resources and selections often fail to yield molecules with affinities sufficient for molecular diagnostics or therapeutics. Toward a selection technique that can efficiently and reproducibly generate high performance aptamers, we have developed a microfluidic selection process (M-SELEX) that can be used to obtain high affinity aptamers against diverse protein targets. Here, we isolated DNA aptamers against three protein targets with different isoelectric points (pI) using a common protocol. After only three rounds of selection, we discovered novel aptamer sequences that bind to platelet derived growth factor B (PDGF-BB; pI = 9.3) and thrombin (pI = 8.3) with respective dissociation constants (K(d)) of 0.028 nM and 0.33 nM, which are both superior to previously reported aptamers against these targets. In parallel, we discovered a new aptamer that binds to apolipoprotein E3 (ApoE; pI = 5.3) with a K(d) of 3.1 nM. Furthermore, we observe that the net protein charge may exert influence on the affinity of the selected aptamers. To further explore this relationship, we performed selections against PDGF-BB under different pH conditions using the same selection protocol, and report an inverse correlation between protein charge and aptamer K(d).

Citing Articles

Research Progress in Small-Molecule Detection Using Aptamer-Based SERS Techniques.

Zheng L, Ye Q, Wang M, Sun F, Chen Q, Yu X Biosensors (Basel). 2025; 15(1).

PMID: 39852080 PMC: 11764255. DOI: 10.3390/bios15010029.


Fluorometric and Colorimetric Method for SARS-CoV-2 Detection Using Designed Aptamer Display Particles.

Park K, Choi A, Park T, Pack S Biosensors (Basel). 2024; 14(3).

PMID: 38534220 PMC: 10968392. DOI: 10.3390/bios14030113.


Molecular Targets of Aptamers in Gastrointestinal Cancers: Cancer Detection, Therapeutic Applications, and Associated Mechanisms.

Goh K, Stephen A, Wu Y, Sim M, Batumalaie K, Gopinath S J Cancer. 2023; 14(13):2491-2516.

PMID: 37670975 PMC: 10475355. DOI: 10.7150/jca.85260.


Wearable chemical sensors for biomarker discovery in the omics era.

Sempionatto J, Lasalde-Ramirez J, Mahato K, Wang J, Gao W Nat Rev Chem. 2023; 6(12):899-915.

PMID: 37117704 PMC: 9666953. DOI: 10.1038/s41570-022-00439-w.


The Influence of Protein Charge and Molecular Weight on the Affinity of Aptamers.

Drees A, Trinh T, Fischer M Pharmaceuticals (Basel). 2023; 16(3).

PMID: 36986556 PMC: 10054347. DOI: 10.3390/ph16030457.


References
1.
Vaught J, Bock C, Carter J, Fitzwater T, Otis M, Schneider D . Expanding the chemistry of DNA for in vitro selection. J Am Chem Soc. 2010; 132(12):4141-51. DOI: 10.1021/ja908035g. View

2.
Ghosh G, Huang D, Huxford T . Molecular mimicry of the NF-kappaB DNA target site by a selected RNA aptamer. Curr Opin Struct Biol. 2004; 14(1):21-7. DOI: 10.1016/j.sbi.2004.01.004. View

3.
Humphrey W, Dalke A, Schulten K . VMD: visual molecular dynamics. J Mol Graph. 1996; 14(1):33-8, 27-8. DOI: 10.1016/0263-7855(96)00018-5. View

4.
Hall B, Micheletti J, Satya P, Ogle K, Pollard J, Ellington A . Design, synthesis, and amplification of DNA pools for in vitro selection. Curr Protoc Nucleic Acid Chem. 2009; Chapter 9:Unit 9.2. DOI: 10.1002/0471142700.nc0902s39. View

5.
Bock L, Griffin L, Latham J, Vermaas E, Toole J . Selection of single-stranded DNA molecules that bind and inhibit human thrombin. Nature. 1992; 355(6360):564-6. DOI: 10.1038/355564a0. View