» Articles » PMID: 21802687

Detection and Quantification of Coronary Atherosclerotic Plaque by 64-slice Multidetector CT: a Systematic Head-to-head Comparison with Intravascular Ultrasound

Abstract

Objective: We evaluated the ability of 64-slice multidetector computed tomography (MDCT)-derived plaque parameters to detect and quantify coronary atherosclerosis, using intravascular ultrasound (IVUS) as the reference standard.

Methods: In 32 patients, IVUS and 64-MDCT was performed. The MDCT and IVUS datasets of 44 coronary arteries were co-registered using a newly developed fusion technique and quantitative parameters were derived from both imaging modalities. The threshold of >0.5 mm of maximum wall thickness was used to establish plaque presence on MDCT and IVUS.

Results: We analyzed 1364 coregistered 1-mm coronary cross-sections and 255 segments of 5-mm length. Compared with IVUS, 64-MDCT enabled correct detection in 957 of 1109 cross-sections containing plaque (sensitivity 86%). In 180 of 255 cross-sections atherosclerosis was correctly excluded (specificity 71%). On the segmental level, MDCT detected 213 of 220 segments with any atherosclerotic plaque (sensitivity 96%), whereas the presence of any plaque was correctly ruled out in 28 of 32 segments (specificity 88%). Interobserver agreement for the detection of atherosclerotic cross-sections was moderate (Cohen's kappa coefficient K=0.51), but excellent for the atherosclerotic segments (K=1.0). Pearson's correlation coefficient for vessel plaque volumes measured by MDCT and IVUS was r=0.91 (p<0.001). Bland-Altman analysis showed a slight non-significant underestimation of any plaque volume by MDCT (p=0.5), with a trend to underestimate noncalcified and overestimate mixed/calcified plaque volumes (p=0.22 and p=0.87 respectively).

Conclusion: MDCT is able to detect and quantify atherosclerotic plaque. Further improvement in CT resolution is necessary for more reliable assessment of very small and distal coronary plaques.

Citing Articles

Technical principles, benefits, challenges, and applications of photon counting computed tomography in coronary imaging: a narrative review.

Meloni A, Maffei E, Positano V, Clemente A, De Gori C, Berti S Cardiovasc Diagn Ther. 2024; 14(4):698-724.

PMID: 39263472 PMC: 11384460. DOI: 10.21037/cdt-24-52.


Atherosclerosis evaluation and cardiovascular risk estimation using coronary computed tomography angiography.

Nurmohamed N, van Rosendael A, Danad I, Ngo-Metzger Q, Taub P, Ray K Eur Heart J. 2024; 45(20):1783-1800.

PMID: 38606889 PMC: 11129796. DOI: 10.1093/eurheartj/ehae190.


Automatic Quantification of Local Plaque Thickness Differences as Assessed by Serial Coronary Computed Tomography Angiography Using Scan-Quality-Based Vessel-Specific Thresholds.

van Driest F, Broersen A, van der Geest R, Jukema J, Scholte A, Dijkstra J Cardiol Ther. 2023; 13(1):103-116.

PMID: 38062285 PMC: 10899547. DOI: 10.1007/s40119-023-00341-6.


Multislice computerized tomography coronary angiography can be a comparable tool to intravascular ultrasound in evaluating "true" coronary artery bifurcations.

Radunovic A, Vidakovic R, Timcic S, Odanovic N, Stefanovic M, Lipovac M Front Cardiovasc Med. 2023; 10:1292517.

PMID: 38028491 PMC: 10657987. DOI: 10.3389/fcvm.2023.1292517.


Clinical applications of cardiac computed tomography: a consensus paper of the European Association of Cardiovascular Imaging-part II.

Pontone G, Rossi A, Guglielmo M, Dweck M, Gaemperli O, Nieman K Eur Heart J Cardiovasc Imaging. 2022; 23(4):e136-e161.

PMID: 35175348 PMC: 8944330. DOI: 10.1093/ehjci/jeab292.