» Articles » PMID: 21771333

A 4D IMRT Planning Method Using Deformable Image Registration to Improve Normal Tissue Sparing with Contemporary Delivery Techniques

Overview
Journal Radiat Oncol
Publisher Biomed Central
Specialties Oncology
Radiology
Date 2011 Jul 21
PMID 21771333
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

We propose a planning method to design true 4-dimensional (4D) intensity-modulated radiotherapy (IMRT) plans, called the t4Dplan method, in which the planning target volume (PTV) of the individual phases of the 4D computed tomography (CT) and the conventional PTV receive non-uniform doses but the cumulative dose to the PTV of each phase, computed using deformable image registration (DIR), are uniform. The non-uniform dose prescription for the conventional PTV was obtained by solving linear equations that required motion-convolved 4D dose to be uniform to the PTV for the end-exhalation phase (PTV50) and by constraining maximum inhomogeneity to 20%. A plug-in code to the treatment planning system was developed to perform the IMRT optimization based on this non-uniform PTV dose prescription. The 4D dose was obtained by summing the mapped doses from individual phases of the 4D CT using DIR. This 4D dose distribution was compared with that of the internal target volume (ITV) method. The robustness of the 4D plans over the course of radiotherapy was evaluated by computing the 4D dose distributions on repeat 4D CT datasets. Three patients with lung tumors were selected to demonstrate the advantages of the t4Dplan method compared with the commonly used ITV method. The 4D dose distribution using the t4Dplan method resulted in greater normal tissue sparing (such as lung, stomach, liver and heart) than did plans designed using the ITV method. The dose volume histograms of cumulative 4D doses to the PTV50, clinical target volume, lung, spinal cord, liver, and heart on the 4D repeat CTs for the two patients were similar to those for the 4D dose at the time of original planning.

Citing Articles

Spatiotemporal Free-Form Registration Method Assisted by a Minimum Spanning Tree During Discontinuous Transformations.

Bae J, Yoon S, Vania M, Lee D J Digit Imaging. 2021; 34(1):190-203.

PMID: 33483863 PMC: 7887135. DOI: 10.1007/s10278-020-00409-y.


Robust Optimization of SBRT Planning for Patients With Early Stage Non-Small Cell Lung Cancer.

Shang H, Pu Y, Wang Y Technol Cancer Res Treat. 2020; 19:1533033820916505.

PMID: 32314663 PMC: 7175055. DOI: 10.1177/1533033820916505.


Dosimetric study of three-dimensional static and dynamic SBRT radiotherapy for hepatocellular carcinoma based on 4DCT image deformable registration.

Ma C, Duan J, Yu S, Ma C J Appl Clin Med Phys. 2020; 21(2):60-66.

PMID: 31889422 PMC: 7020978. DOI: 10.1002/acm2.12811.


Automatic large quantity landmark pairs detection in 4DCT lung images.

Fu Y, Wu X, Thomas A, Li H, Yang D Med Phys. 2019; 46(10):4490-4501.

PMID: 31318989 PMC: 8311742. DOI: 10.1002/mp.13726.


Inverse 4D conformal planning for lung SBRT using particle swarm optimization.

Modiri A, Gu X, Hagan A, Bland R, Iyengar P, Timmerman R Phys Med Biol. 2016; 61(16):6181-202.

PMID: 27476472 PMC: 5175212. DOI: 10.1088/0031-9155/61/16/6181.


References
1.
Engelsman M, Sharp G, Bortfeld T, Onimaru R, Shirato H . How much margin reduction is possible through gating or breath hold?. Phys Med Biol. 2005; 50(3):477-90. DOI: 10.1088/0031-9155/50/3/006. View

2.
Mageras G, Pevsner A, Yorke E, Rosenzweig K, Ford E, Hertanto A . Measurement of lung tumor motion using respiration-correlated CT. Int J Radiat Oncol Biol Phys. 2004; 60(3):933-41. DOI: 10.1016/j.ijrobp.2004.06.021. View

3.
Werner R, Ehrhardt J, Frenzel T, Saring D, Lu W, Low D . Motion artifact reducing reconstruction of 4D CT image data for the analysis of respiratory dynamics. Methods Inf Med. 2007; 46(3):254-60. DOI: 10.1160/ME9040. View

4.
Keall P, Mageras G, Balter J, Emery R, Forster K, Jiang S . The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys. 2006; 33(10):3874-900. DOI: 10.1118/1.2349696. View

5.
Wolthaus J, Schneider C, Sonke J, Van Herk M, Belderbos J, Rossi M . Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. Int J Radiat Oncol Biol Phys. 2006; 65(5):1560-71. DOI: 10.1016/j.ijrobp.2006.04.031. View