» Articles » PMID: 21604768

Development of a Low-resource RNA Extraction Cassette Based on Surface Tension Valves

Overview
Date 2011 May 25
PMID 21604768
Citations 30
Authors
Affiliations
Soon will be listed here.
Abstract

Nucleic acid-based diagnostics are highly sensitive and specific, but are easily disrupted by the presence of interferents in biological samples. In a laboratory or hospital setting, the influence of these interferents can be minimized using an RNA or DNA extraction procedure prior to analysis. However, in low-resource settings, limited access to specialized instrumentation and trained personnel presents challenges that impede sample preparation. We have developed a self-contained nucleic acid extraction cassette suitable for operation in a low-resource setting. This simple design contains processing solutions preloaded within a continuous length of 1.6 mm inner diameter Tygon tubing. Processing solutions are separated by air gaps and held in place during processing by the surface tension forces at the liquid-air interface, viz. surface tension valves. Nucleic acids preferentially adsorbed to silica-coated magnetic particles are separated from sample interferents using an external magnet to transfer the nucleic acid biomarker through successive solutions to precipitate, wash and elute in the final cassette solution. The efficiency of the extraction cassette was evaluated using quantitative reverse transcriptase PCR (qRT-PCR) following extraction of respiratory syncytial virus (RSV) RNA. RNA was recovered from TE buffer or from lysates of RSV infected HEp-2 cells with 55 and 33% efficiency, respectively, of the Qiagen RNeasy kit. Recovery of RSV RNA from RSV infected HEp-2 cells was similar at 30% of the RNeasy kit. An overall limit of detection after extraction was determined to be nearly identical (97.5%) to a laboratory-based commercially available kit. These results indicate that this extraction cassette design has the potential to be an effective sample preparation device suitable for use in a low-resource setting.

Citing Articles

Programmable magnetic robot (ProMagBot) for automated nucleic acid extraction at the point of need.

Politza A, Liu T, Guan W Lab Chip. 2023; 23(17):3882-3892.

PMID: 37551930 PMC: 11218199. DOI: 10.1039/d3lc00545c.


Magnetic Bead Processing Enables Sensitive Ligation-Based Detection of HIV Drug Resistance Mutations.

Nelson D, Leelawong M, Pask M, Wester C, Aliyu M, Haselton F Anal Chem. 2022; 94(5):2625-2632.

PMID: 35077642 PMC: 11127743. DOI: 10.1021/acs.analchem.1c05040.


Development of an Automated, Non-Enzymatic Nucleic Acid Amplification Test.

Zimmers Z, Boyd A, Stepp H, Adams N, Haselton F Micromachines (Basel). 2021; 12(10).

PMID: 34683255 PMC: 8538085. DOI: 10.3390/mi12101204.


An Overview on Microfluidic Systems for Nucleic Acids Extraction from Human Raw Samples.

Obino D, Vassalli M, Franceschi A, Alessandrini A, Facci P, Viti F Sensors (Basel). 2021; 21(9).

PMID: 33925730 PMC: 8125272. DOI: 10.3390/s21093058.


Plasmonic nanobiosensors for detection of microRNA cancer biomarkers in clinical samples.

Crawford B, Wang H, Stolarchuk C, von Furstenberg R, Strobbia P, Zhang D Analyst. 2020; 145(13):4587-4594.

PMID: 32436503 PMC: 9532004. DOI: 10.1039/d0an00193g.


References
1.
Niemz A, Ferguson T, Boyle D . Point-of-care nucleic acid testing for infectious diseases. Trends Biotechnol. 2011; 29(5):240-50. PMC: 3746968. DOI: 10.1016/j.tibtech.2011.01.007. View

2.
Sur K, McFall S, Yeh E, Jangam S, Hayden M, Stroupe S . Immiscible phase nucleic acid purification eliminates PCR inhibitors with a single pass of paramagnetic particles through a hydrophobic liquid. J Mol Diagn. 2010; 12(5):620-8. PMC: 2928426. DOI: 10.2353/jmoldx.2010.090190. View

3.
Hagan K, Reedy C, Uchimoto M, Basu D, Engel D, Landers J . An integrated, valveless system for microfluidic purification and reverse transcription-PCR amplification of RNA for detection of infectious agents. Lab Chip. 2010; 11(5):957-61. DOI: 10.1039/c0lc00136h. View

4.
Chen D, Mauk M, Qiu X, Liu C, Kim J, Ramprasad S . An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids. Biomed Microdevices. 2010; 12(4):705-19. PMC: 2924744. DOI: 10.1007/s10544-010-9423-4. View

5.
Wilson I . Inhibition and facilitation of nucleic acid amplification. Appl Environ Microbiol. 1997; 63(10):3741-51. PMC: 168683. DOI: 10.1128/aem.63.10.3741-3751.1997. View