» Articles » PMID: 21511561

Bias Field Inconsistency Correction of Motion-scattered Multislice MRI for Improved 3D Image Reconstruction

Overview
Date 2011 Apr 23
PMID 21511561
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

A common solution to clinical MR imaging in the presence of large anatomical motion is to use fast multislice 2D studies to reduce slice acquisition time and provide clinically usable slice data. Recently, techniques have been developed which retrospectively correct large scale 3D motion between individual slices allowing the formation of a geometrically correct 3D volume from the multiple slice stacks. One challenge, however, in the final reconstruction process is the possibility of varying intensity bias in the slice data, typically due to the motion of the anatomy relative to imaging coils. As a result, slices which cover the same region of anatomy at different times may exhibit different sensitivity. This bias field inconsistency can induce artifacts in the final 3D reconstruction that can impact both clinical interpretation of key tissue boundaries and the automated analysis of the data. Here we describe a framework to estimate and correct the bias field inconsistency in each slice collectively across all motion corrupted image slices. Experiments using synthetic and clinical data show that the proposed method reduces intensity variability in tissues and improves the distinction between key tissue types.

Citing Articles

Structural and functional fetal cardiac imaging using low field (0.55 T) MRI.

Zhang C, Cleri M, Woodgate T, Gilliland P, Bansal S, Aviles Verdera J Front Pediatr. 2024; 12:1418645.

PMID: 39318614 PMC: 11421172. DOI: 10.3389/fped.2024.1418645.


Learning from pseudo-labels: deep networks improve consistency in longitudinal brain volume estimation.

Zhan G, Wang D, Cabezas M, Bai L, Kyle K, Ouyang W Front Neurosci. 2023; 17:1196087.

PMID: 37483345 PMC: 10358358. DOI: 10.3389/fnins.2023.1196087.


Motion corrected MRI differentiates male and female human brain growth trajectories from mid-gestation.

Studholme C, Kroenke C, Dighe M Nat Commun. 2020; 11(1):3038.

PMID: 32546755 PMC: 7297991. DOI: 10.1038/s41467-020-16763-y.


In utero MRI identifies consequences of early-gestation alcohol drinking on fetal brain development in rhesus macaques.

Wang X, Cuzon Carlson V, Studholme C, Newman N, Ford M, Grant K Proc Natl Acad Sci U S A. 2020; 117(18):10035-10044.

PMID: 32312804 PMC: 7211988. DOI: 10.1073/pnas.1919048117.


Anatomical and diffusion MRI brain atlases of the fetal rhesus macaque brain at 85, 110 and 135 days gestation.

Liu Z, Wang X, Newman N, Grant K, Studholme C, Kroenke C Neuroimage. 2019; 206:116310.

PMID: 31669303 PMC: 6980966. DOI: 10.1016/j.neuroimage.2019.116310.


References
1.
Collins C, Smith M . Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Med. 2001; 45(4):692-9. DOI: 10.1002/mrm.1092. View

2.
Levine D, Barnes P, Sher S, Semelka R, Li W, McArdle C . Fetal fast MR imaging: reproducibility, technical quality, and conspicuity of anatomy. Radiology. 1998; 206(2):549-54. DOI: 10.1148/radiology.206.2.9457211. View

3.
Rousseau F, Kim K, Studholme C, Koob M, Dietemann J . On super-resolution for fetal brain MRI. Med Image Comput Comput Assist Interv. 2010; 13(Pt 2):355-62. PMC: 3319126. DOI: 10.1007/978-3-642-15745-5_44. View

4.
Habas P, Kim K, Corbett-Detig J, Rousseau F, Glenn O, Barkovich A . A spatiotemporal atlas of MR intensity, tissue probability and shape of the fetal brain with application to segmentation. Neuroimage. 2010; 53(2):460-70. PMC: 2930902. DOI: 10.1016/j.neuroimage.2010.06.054. View

5.
Belaroussi B, Milles J, Carme S, Zhu Y, Benoit-Cattin H . Intensity non-uniformity correction in MRI: existing methods and their validation. Med Image Anal. 2005; 10(2):234-46. DOI: 10.1016/j.media.2005.09.004. View