Establishment of the Epithelial Attachment and Connective Tissue Adaptation to Implants Installed Under the Concept of "platform Switching": a Histologic Study in Minipigs

Overview
Specialty Dentistry
Date 2011 Apr 16
PMID 21492239
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: To validate the "platform switching" concept at oral implants with respect to the preservation of the alveolar crestal bone levels in an animal model.

Material & Methods: Five minipigs received three implants each with a 0.25 mm implant/abutment mismatch and were placed flush (T(0)), 1 mm below (T(1)) and 1 mm above (T(+1)) the alveolar bony crest, and as a control, one conventionally restored implant placed at the bone level. The implants were randomly inserted flapless into the mandible. Four months after implant insertion, the animals were sacrificed, and undecalcified block sections were obtained and used for histological analyses.

Results: The mean values for peri-implant bone resorption were 1.09 ± 0.59 mm (Control), 0.51 (± 0.27 mm, T(0)), 0.50 (± 0.46 mm, T(+1)) and 1.30 (± 0.21 mm, T(-1)), respectively. Statistically significant differences (P<0.05) were found among the test (T(0), T(-1)) and the control sites. Control implants presented an average biologic width length of 3.20 mm (± 0.33), with a connective tissue adaptation compartment of 1.29 mm (± 0.53) and an epithelial attachment of 1.91 mm (± 0.71). T(0), T(+1) and T(-1) implants presented with a mean biologic width of 1.97 mm (± 1.20), 2.70 mm (± 1.36) and 2.84 mm (± 0.90), respectively, with a connective tissue adaptation compartment of 1.21 mm (± 0.97), 1.21 mm (± 0.65) and 1.50 mm (± 0.70) and an epithelial attachment of 0.84 mm (± 0.93), 1.66 mm (± 0.88) and 1.35 mm (± 0.44), respectively. Differences between the configurations were mainly associated with the length of the epithelial attachment. The epithelial attachment was significantly longer in the C sites than in T(0) (P=0.014). However, no other differences between configurations were detected.

Conclusion: If the implants are positioned at the level of the alveolar bony crest, the platform-switching concept may have a minor impact on the length of the epithelial attachment (0.84 vs. 1.91 mm), while the connective tissue adaptation compartment remains relatively unaffected. Moreover, platform switching resulted in less resorption of the alveolar crest (0.58 mm).

Citing Articles

Contour Analysis of Three-Dimensional Peri-Implant Mucosal Model as an Endpoint Analysis of Photofunctionalization Effects on Implant Abutment Materials.

Razali M, Chai W, Omar R, Ngeow W Materials (Basel). 2023; 16(16).

PMID: 37629819 PMC: 10456501. DOI: 10.3390/ma16165529.


Contour angle and peri-implant tissue height: Two interrelated features of the implant supracrestal complex.

Puisys A, Janda M, Auzbikaviciute V, Gallucci G, Mattheos N Clin Exp Dent Res. 2023; 9(3):418-424.

PMID: 36988518 PMC: 10280599. DOI: 10.1002/cre2.731.


Radiographic evaluation of a cross-shaped incision technique for thick-gingiva and thin-gingiva patients treated with implant-supported fixed prosthesis.

Luo W, Wang X, Chen Y, Hong Y, Qu Y, Man Y BMC Oral Health. 2021; 21(1):655.

PMID: 34922521 PMC: 8684668. DOI: 10.1186/s12903-021-02019-8.


Pre-Clinical Models in Implant Dentistry: Past, Present, Future.

Blanc-Sylvestre N, Bouchard P, Chaussain C, Bardet C Biomedicines. 2021; 9(11).

PMID: 34829765 PMC: 8615291. DOI: 10.3390/biomedicines9111538.


Mechanical Performance of Chairside Ceramic CAD/CAM Restorations and Zirconia Abutments with Different Internal Implant Connections: In Vitro Study and Finite Element Analysis.

Giner S, Bartolome J, Gomez-Cogolludo P, Castellote C, Pradies G Materials (Basel). 2021; 14(17).

PMID: 34501107 PMC: 8434075. DOI: 10.3390/ma14175009.