» Articles » PMID: 21294631

A Comparison of Cooling Techniques in Firefighters After a Live Burn Evolution

Overview
Publisher Informa Healthcare
Specialty Emergency Medicine
Date 2011 Feb 8
PMID 21294631
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: We compared the use of two active cooling devices with passive cooling in a moderate-temperature (≈ 22 °C) environment on heart rate (HR) and core temperature (T(c)) recovery when applied to firefighters following 20 minutes of fire suppression.

Methods: Firefighters (23 men, two women) performed 20 minutes of fire suppression at a live-fire evolution. Immediately following the evolution, the subjects removed their thermal protective clothing and were randomized to receive forearm immersion (FI), ice water perfused cooling vest (CV), or passive (P) cooling in an air-conditioned medical trailer for 30 minutes. Heart rate and deep gastric temperature were monitored every 5 minutes during recovery.

Results: A single 20-minute bout of fire suppression resulted in near-maximal mean ± standard deviation HR (175 ± 13 b min(-1), P; 172 ± 20 b·min(-1), FI; 177 ± 12 b·min(-1), CV) when compared with baseline (p < 0.001), a rapid and substantial rise in T(c) (38.2° ± 0.7°, P; 38.3° ± 0.4°, FI; 38.3° ± 0.3°, CV) compared with baseline (p < 0.001), and body mass lost from sweating of nearly 1 kilogram. Cooling rates (°C·min) differed (p = 0.036) by device, with FI (0.05 ± 0.04) providing higher rates than P (0.03 ± 0.02) or CV (0.03 ± 0.04), although differences over 30 minutes were small and recovery of body temperature was incomplete in all groups.

Conclusions: During 30 minutes of recovery following a 20-minute bout of fire suppression in a training academy setting, there is a slightly higher cooling rate for FI and no apparent benefit to CV when compared with P cooling in a moderate temperature environment.

Citing Articles

Fueling the Firefighter and Tactical Athlete with Creatine: A Narrative Review of a Key Nutrient for Public Safety.

Gonzalez D, Forbes S, Zapp A, Jagim A, Luedke J, Dickerson B Nutrients. 2024; 16(19).

PMID: 39408252 PMC: 11478539. DOI: 10.3390/nu16193285.


Evaluation of self-contained breathing apparatus (SCBA) weight on firefighter stamina, comfort, and postural stability.

Kesler R, Powell J, Nguyen D, Massey K, Joshi S, Xu S Ergonomics. 2024; :1-14.

PMID: 38972717 PMC: 11704086. DOI: 10.1080/00140139.2024.2375026.


Heat stroke management during the COVID-19 pandemic: Recommendations from the experts in Japan (2nd edition).

Kanda J, Wakasugi M, Kondo Y, Ueno S, Kaneko H, Okada Y Acute Med Surg. 2023; 10(1):e827.

PMID: 37056485 PMC: 10086676. DOI: 10.1002/ams2.827.


Exploring First Responders' Use and Perceptions on Continuous Health and Environmental Monitoring.

Grothe J, Tucker S, Blake A, Achutan C, Medcalf S, Suwondo T Int J Environ Res Public Health. 2023; 20(6).

PMID: 36981694 PMC: 10048923. DOI: 10.3390/ijerph20064787.


Wayfinding of Firefighters in Dark and Complex Environments.

Lin B, Lin C, Kung C, Lin Y, Chou C, Chuang Y Int J Environ Res Public Health. 2021; 18(15).

PMID: 34360307 PMC: 8345462. DOI: 10.3390/ijerph18158014.


References
1.
Smith D, Manning T, Petruzzello S . Effect of strenuous live-fire drills on cardiovascular and psychological responses of recruit firefighters. Ergonomics. 2001; 44(3):244-54. DOI: 10.1080/00140130121115. View

2.
Giesbrecht G, Jamieson C, Cahill F . Cooling hyperthermic firefighters by immersing forearms and hands in 10 degrees C and 20 degrees C water. Aviat Space Environ Med. 2007; 78(6):561-7. View

3.
Jackson A, Pollock M . Generalized equations for predicting body density of men. Br J Nutr. 1978; 40(3):497-504. DOI: 10.1079/bjn19780152. View

4.
Hostler D, Reis S, Bednez J, Kerin S, Suyama J . Comparison of active cooling devices with passive cooling for rehabilitation of firefighters performing exercise in thermal protective clothing: a report from the Fireground Rehab Evaluation (FIRE) trial. Prehosp Emerg Care. 2010; 14(3):300-9. PMC: 2879165. DOI: 10.3109/10903121003770654. View

5.
Malley K, Goldstein A, Aldrich T, Kelly K, Weiden M, Coplan N . Effects of fire fighting uniform (modern, modified modern, and traditional) design changes on exercise duration in New York City Firefighters. J Occup Environ Med. 1999; 41(12):1104-15. DOI: 10.1097/00043764-199912000-00015. View