» Articles » PMID: 36981694

Exploring First Responders' Use and Perceptions on Continuous Health and Environmental Monitoring

Overview
Publisher MDPI
Date 2023 Mar 29
PMID 36981694
Authors
Affiliations
Soon will be listed here.
Abstract

First responders lose their lives in the line of duty each year, and many of these deaths result from strenuous physical exertion and exposure to harmful environmental agents. Continuous health monitoring may detect diseases and alert the first responder when vital signs are reaching critical levels. However, continuous monitoring must be acceptable to first responders. The purpose of this study was to discover first responders' current use of wearable technology, their perceptions of what health and environmental indicators should be monitored, and who should be permitted to monitor them. The survey was sent to 645 first responders employed by 24 local fire department stations. A total of 115 (17.8%) first responders answered the survey and 112 were used for analysis. Results found first responders perceived a need for health and environmental monitoring. The health and environmental indicators that respondents perceived as most important for monitoring in the field were heart rate (98.2%) and carbon monoxide (100%), respectively. Overall, using and wearing monitoring devices was not age-dependent and health and environmental concerns were important for first responders at any stage of their career. However, current wearable technology does not seem to be a viable solution for first responders due to device expense and durability issues.

Citing Articles

The Effects of Self-Monitoring Using a Smartwatch and Smartphone App on Stress Awareness, Self-Efficacy, and Well-Being-Related Outcomes in Police Officers: Longitudinal Mixed Design Study.

de Vries H, Delahaij R, van Zwieten M, Verhoef H, Kamphuis W JMIR Mhealth Uhealth. 2025; 13:e60708.

PMID: 39881435 PMC: 11793834. DOI: 10.2196/60708.


Wearable devices for out-of-hospital cardiac arrest: A population survey on the willingness to adhere.

Lingawi S, Hutton J, Khalili M, Dainty K, Grunau B, Shadgan B J Am Coll Emerg Physicians Open. 2024; 5(5):e13268.

PMID: 39193083 PMC: 11345495. DOI: 10.1002/emp2.13268.


Exploring wearable technology use and importance of health monitoring in the hazardous occupations of first responders and professional drivers.

Tucker S, Jonnalagadda S, Beseler C, Yoder A, Fruhling A J Occup Health. 2024; 66(1).

PMID: 38332724 PMC: 11020306. DOI: 10.1093/joccuh/uiad002.

References
1.
McQuerry M, Barker R, DenHartog E . Relationship between novel design modifications and heat stress relief in structural firefighters' protective clothing. Appl Ergon. 2018; 70:260-268. DOI: 10.1016/j.apergo.2018.03.004. View

2.
Bergmann J, Chandaria V, McGregor A . Wearable and implantable sensors: the patient's perspective. Sensors (Basel). 2013; 12(12):16695-709. PMC: 3571806. DOI: 10.3390/s121216695. View

3.
Barnard R, Weber J . Carbon monoxide: a hazard to fire fighters. Arch Environ Health. 1979; 34(4):255-7. DOI: 10.1080/00039896.1979.10667410. View

4.
Smith D, Petruzzello S, Kramer J, Misner J . The effects of different thermal environments on the physiological and psychological responses of firefighters to a training drill. Ergonomics. 1997; 40(4):500-10. DOI: 10.1080/001401397188125. View

5.
Horn G, Kesler R, Motl R, Hsiao-Wecksler E, Klaren R, Ensari I . Physiological responses to simulated firefighter exercise protocols in varying environments. Ergonomics. 2015; 58(6):1012-21. DOI: 10.1080/00140139.2014.997806. View