Low Noise Level Unmasks Late Potentials on Signal-averaged Electrocardiography

Overview
Date 2010 Oct 21
PMID 20959882
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Identification of late potentials requires the reduction of random noise by signal averaging. The importance of using a very low noise level (NL) as the end point of the averaging process in patients with ventricular tachycardia, the variation of results when a lower than standard NL was used and the modification of the sensitivity of the test when a very low NL was reached were evaluated.

Methods And Results: Signal-averaged electrocardiograms were recorded in 36 patients with ischemic heart disease and spontaneous or induced sustained or nonsustained ventricular tachycardia. Thirteen patients showed negative or indeterminate results on recordings with an NL of 0.3 μV. Eight patients (group 1) underwent a second recording with an NL of 0.1 μV. Eight normal volunteers constituted the control group (group 2). The total duration of the filtered QRS vector magnitude (QRSd), the root mean square voltage of the terminal 40 ms of the vector magnitude (RMS(40)) and the low amplitude signal duration under 40 μV in the terminal portion of the vector magnitude (LAS) modifications were evaluated. A significant difference (P<0.01) in these parameters was observed in group 1 (15.88%, 48.25% and 68.5%, respectively) when both recordings were compared. Tests were positive in all patients (100%) with NL reduction. In group 2, tests were negative in all patients (100%) at both NLs (0.3 μV and 0.1 μV). QRSd was 1.18% longer, RMS(40) was 1.38% lower and LAS was 3.55% longer with NL reduction.

Conclusion: Late potentials in patients with ischemic heart disease, ventricular tachycardia, and a negative or indeterminate signal-averaged electrocardiogram may be detected if the NL is reduced to 0.1 μV. Reduction of the NL increased the sensitivity of the test without modifying its specificity.

Citing Articles

Increasing averaging beats improves the test accuracy on Holter-based late potentials in patients with myocardial infarction.

Hashimoto K, Harada N, Kimata M, Kawamura Y, Fujita N, Sekizawa A Ann Noninvasive Electrocardiol. 2023; 28(6):e13089.

PMID: 37724719 PMC: 10646378. DOI: 10.1111/anec.13089.


Ventricular depolarisation vectors in exercise induced myocardial ischaemia.

Vellani C, Yusuf M, Mahmud S, Hashmi S Sci Rep. 2017; 7(1):14649.

PMID: 29116106 PMC: 5676957. DOI: 10.1038/s41598-017-14865-0.

References
1.
Simson M . Use of signals in the terminal QRS complex to identify patients with ventricular tachycardia after myocardial infarction. Circulation. 1981; 64(2):235-42. DOI: 10.1161/01.cir.64.2.235. View

2.
Berbari E, Scherlag B, Hope R, LAZZARA R . Recording from the body surface of arrhythmogenic ventricular activity during the S-T segment. Am J Cardiol. 1978; 41(4):697-702. DOI: 10.1016/0002-9149(78)90820-2. View

3.
Kuchar D, Thorburn C, Sammel N . Prediction of serious arrhythmic events after myocardial infarction: signal-averaged electrocardiogram, Holter monitoring and radionuclide ventriculography. J Am Coll Cardiol. 1987; 9(3):531-8. DOI: 10.1016/s0735-1097(87)80045-1. View

4.
Madias J . Standard electrocardiographic and signal-averaged electrocardiographic changes in congestive heart failure. Congest Heart Fail. 2005; 11(5):266-71. DOI: 10.1111/j.1527-5299.2005.04484.x. View

5.
Ribeiro A, Cavalvanti P, Lombardi F, Nunes M, Barros M, da Costa Rocha M . Prognostic value of signal-averaged electrocardiogram in Chagas disease. J Cardiovasc Electrophysiol. 2008; 19(5):502-9. DOI: 10.1111/j.1540-8167.2007.01088.x. View