» Articles » PMID: 20876972

In Vivo Transcranial Cavitation Threshold Detection During Ultrasound-induced Blood-brain Barrier Opening in Mice

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2010 Sep 30
PMID 20876972
Citations 114
Authors
Affiliations
Soon will be listed here.
Abstract

The in vivo cavitation response associated with blood-brain barrier (BBB) opening as induced by transcranial focused ultrasound (FUS) in conjunction with microbubbles was studied in order to better identify the underlying mechanism in its noninvasive application. A cylindrically focused hydrophone, confocal with the FUS transducer, was used as a passive cavitation detector (PCD) to identify the threshold of inertial cavitation (IC) in the presence of Definity® microbubbles (mean diameter range: 1.1-3.3 µm, Lantheus Medical Imaging, MA, USA). A vessel phantom was first used to determine the reliability of the PCD prior to in vivo use. A cerebral blood vessel was simulated by generating a cylindrical channel of 610 µm in diameter inside a polyacrylamide gel and by saturating its volume with microbubbles. The microbubbles were sonicated through an excised mouse skull. Second, the same PCD setup was employed for in vivo noninvasive (i.e. transdermal and transcranial) cavitation detection during BBB opening. After the intravenous administration of Definity® microbubbles, pulsed FUS was applied (frequency: 1.525 or 1.5 MHz, peak-rarefactional pressure: 0.15-0.60 MPa, duty cycle: 20%, PRF: 10 Hz, duration: 1 min with a 30 s interval) to the right hippocampus of twenty-six (n = 26) mice in vivo through intact scalp and skull. T1 and T2-weighted MR images were used to verify the BBB opening. A spectrogram was generated at each pressure in order to detect the IC onset and duration. The threshold of BBB opening was found to be at a 0.30 MPa peak-rarefactional pressure in vivo. Both the phantom and in vivo studies indicated that the IC pressure threshold had a peak-rarefactional amplitude of 0.45 MPa. This indicated that BBB opening may not require IC at or near the threshold. Histological analysis showed that BBB opening could be induced without any cellular damage at 0.30 and 0.45 MPa. In conclusion, the cavitation response could be detected without craniotomy in mice and IC may not be required for BBB opening at relatively low pressures.

Citing Articles

Investigation of Sonication Parameters for Large-Volume Focused Ultrasound-Mediated Blood-Brain Barrier Permeability Enhancement Using a Clinical-Prototype Hemispherical Phased Array.

McMahon D, Jones R, Ramdoyal R, Zhuang J, Leavitt D, Hynynen K Pharmaceutics. 2024; 16(10).

PMID: 39458618 PMC: 11510584. DOI: 10.3390/pharmaceutics16101289.


A Transmit-Receive Phased Array for Microbubble-Mediated Focused Ultrasound Brain Therapy in Small Animals.

Lin Y, McMahon D, Jones R, Hynynen K IEEE Trans Biomed Eng. 2024; 72(2):630-644.

PMID: 39312435 PMC: 11875903. DOI: 10.1109/TBME.2024.3466550.


Therapeutic ultrasound transducer technology and monitoring techniques: a review with clinical examples.

Lafond M, Payne A, Lafon C Int J Hyperthermia. 2024; 41(1):2389288.

PMID: 39134055 PMC: 11375802. DOI: 10.1080/02656736.2024.2389288.


Acoustically targeted measurement of transgene expression in the brain.

Seo J, Trippett J, Huang Z, Lee S, Nouraein S, Wang R Sci Adv. 2024; 10(32):eadj7686.

PMID: 39110811 PMC: 11305388. DOI: 10.1126/sciadv.adj7686.


Microbubble-Enhanced Focused Ultrasound for Infiltrating Gliomas.

Seas A, Malla A, Sharifai N, Winkles J, Woodworth G, Anastasiadis P Biomedicines. 2024; 12(6).

PMID: 38927437 PMC: 11200892. DOI: 10.3390/biomedicines12061230.


References
1.
Sassaroli E, Hynynen K . Resonance frequency of microbubbles in small blood vessels: a numerical study. Phys Med Biol. 2005; 50(22):5293-305. DOI: 10.1088/0031-9155/50/22/006. View

2.
Chomas J, Dayton P, May D, Ferrara K . Threshold of fragmentation for ultrasonic contrast agents. J Biomed Opt. 2001; 6(2):141-50. DOI: 10.1117/1.1352752. View

3.
Liu H, Wai Y, Chen W, Chen J, Hsu P, Wu X . Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging. Ultrasound Med Biol. 2008; 34(4):598-606. DOI: 10.1016/j.ultrasmedbio.2008.01.011. View

4.
Baseri B, Choi J, Tung Y, Konofagou E . Multi-modality safety assessment of blood-brain barrier opening using focused ultrasound and definity microbubbles: a short-term study. Ultrasound Med Biol. 2010; 36(9):1445-59. PMC: 3968780. DOI: 10.1016/j.ultrasmedbio.2010.06.005. View

5.
Vlachos F, Tung Y, Konofagou E . Permeability assessment of the focused ultrasound-induced blood-brain barrier opening using dynamic contrast-enhanced MRI. Phys Med Biol. 2010; 55(18):5451-66. PMC: 4005850. DOI: 10.1088/0031-9155/55/18/012. View