» Articles » PMID: 36042266

Guiding and Monitoring Focused Ultrasound Mediated Blood-brain barrier Opening in Rats Using Power Doppler Imaging and Passive Acoustic Mapping

Overview
Journal Sci Rep
Specialty Science
Date 2022 Aug 30
PMID 36042266
Authors
Affiliations
Soon will be listed here.
Abstract

The blood-brain barrier (BBB) prevents harmful toxins from entering brain but can also inhibit therapeutic molecules designed to treat neurodegenerative diseases. Focused ultrasound (FUS) combined with microbubbles can enhance permeability of BBB and is often performed under MRI guidance. We present an all-ultrasound system capable of targeting desired regions to open BBB with millimeter-scale accuracy in two dimensions based on Doppler images. We registered imaging coordinates to FUS coordinates with target registration error of 0.6 ± 0.3 mm and used the system to target microbubbles flowing in cellulose tube in two in vitro scenarios (agarose-embedded and through a rat skull), while receiving echoes on imaging transducer. We created passive acoustic maps from received echoes and found error between intended location in imaging plane and location of pixel with maximum intensity after passive acoustic maps reconstruction to be within 2 mm in 5/6 cases. We validated ultrasound-guided procedure in three in vivo rat brains by delivering MRI contrast agent to cortical regions of rat brains after BBB opening. Landmark-based registration of vascular maps created with MRI and Doppler ultrasound revealed BBB opening inside the intended focus with targeting accuracy within 1.5 mm. Combined use of power Doppler imaging with passive acoustic mapping demonstrates an ultrasound-based solution to guide focused ultrasound with high precision in rodents.

Citing Articles

Volumetric Passive Acoustic Mapping and Cavitation Detection of Nanobubbles under Low-Frequency Insonation.

Shinar H, Ilovitsh T ACS Mater Au. 2025; 5(1):159-169.

PMID: 39802150 PMC: 11718533. DOI: 10.1021/acsmaterialsau.4c00064.


A Transmit-Receive Phased Array for Microbubble-Mediated Focused Ultrasound Brain Therapy in Small Animals.

Lin Y, McMahon D, Jones R, Hynynen K IEEE Trans Biomed Eng. 2024; 72(2):630-644.

PMID: 39312435 PMC: 11875903. DOI: 10.1109/TBME.2024.3466550.


Numerical simulation study on opening blood-brain barrier by ultrasonic cavitation.

Lei W, Chang S, Tian F, Zou X, Hu J, Qian S Ultrason Sonochem. 2024; 109:107005.

PMID: 39098097 PMC: 11345312. DOI: 10.1016/j.ultsonch.2024.107005.


Focused Ultrasound as a Novel Non-Invasive Method for the Delivery of Gold Nanoparticles to Retinal Ganglion Cells.

Park Y, Shin J, Park J, Kim S, Park J, Kim J Transl Vis Sci Technol. 2024; 13(5):5.

PMID: 38713474 PMC: 11086706. DOI: 10.1167/tvst.13.5.5.


Nanomaterials as drug delivery agents for overcoming the blood-brain barrier: A comprehensive review.

Kulkarni M, Patel K, Patel A, Patel S, Desai J, Patel M ADMET DMPK. 2024; 12(1):63-105.

PMID: 38560713 PMC: 10974816. DOI: 10.5599/admet.2043.


References
1.
Airan R, Meyer R, Ellens N, Rhodes K, Farahani K, Pomper M . Noninvasive Targeted Transcranial Neuromodulation via Focused Ultrasound Gated Drug Release from Nanoemulsions. Nano Lett. 2017; 17(2):652-659. PMC: 5362146. DOI: 10.1021/acs.nanolett.6b03517. View

2.
Errico C, Pierre J, Pezet S, Desailly Y, Lenkei Z, Couture O . Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging. Nature. 2015; 527(7579):499-502. DOI: 10.1038/nature16066. View

3.
Tung Y, Vlachos F, Choi J, Deffieux T, Selert K, Konofagou E . In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice. Phys Med Biol. 2010; 55(20):6141-55. PMC: 4005785. DOI: 10.1088/0031-9155/55/20/007. View

4.
Morse S, Pouliopoulos A, Chan T, Copping M, Lin J, Long N . Rapid Short-pulse Ultrasound Delivers Drugs Uniformly across the Murine Blood-Brain Barrier with Negligible Disruption. Radiology. 2019; 291(2):459-466. PMC: 6493324. DOI: 10.1148/radiol.2019181625. View

5.
Chaplin V, Phipps M, Caskey C . A random phased-array for MR-guided transcranial ultrasound neuromodulation in non-human primates. Phys Med Biol. 2018; 63(10):105016. PMC: 6941739. DOI: 10.1088/1361-6560/aabeff. View