» Articles » PMID: 20541882

LC-determination of Five Paraben Preservatives in Saliva and Toothpaste Samples Using UV Detection and a Short Monolithic Column

Overview
Specialty Chemistry
Date 2010 Jun 15
PMID 20541882
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The present study reports the development and application of an HPLC-UV method for the simultaneous separation and determination of five paraben preservatives (methyl-, ethyl-, propyl-, n-butyl- and iso-butyl-paraben) in real samples. All analytes were separated efficiently in less than 20 min using a simple H(2)O:ACN linear gradient and a short monolithic column (50 mm x 4.6mm i.d.) at a flow rate of 3.0mL min(-1). Phenoxyethanol was used as chromatographic internal standard. The method was validated for linearity, limits of detection and quantification, accuracy and precision. Human saliva and toothpaste samples were analyzed after SPE pretreatment on Licrolut RP-18 cartridges. The detection limits varied between 0.1 and 0.3 mg L(-1) in all cases and the percent recoveries between 86 and 113%.

Citing Articles

MIL-68 (Ga) for the extraction of derivatized and non-derivatized parabens from healthcare products.

Pezhhanfar S, Farajzadeh M, Kheirkhah Ghaleh M, Hosseini-Yazdi S, Afshar Mogaddam M Sci Rep. 2023; 13(1):21304.

PMID: 38042936 PMC: 10693546. DOI: 10.1038/s41598-023-48880-1.


Molybdenum disulfide-graphene oxide composites as dispersive solid-phase extraction adsorbents for the enrichment of four paraben preservatives in cosmetics.

Sun W, Hu X, Meng X, Xiang Y, Ye N Mikrochim Acta. 2021; 188(8):256.

PMID: 34268616 DOI: 10.1007/s00604-021-04908-9.


Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector.

Ali H, Alsohaimi I, Khan M, Azam M Pharmaceuticals (Basel). 2020; 13(11).

PMID: 33266462 PMC: 7700590. DOI: 10.3390/ph13110412.


Serum analysis in women and in vitro skin assay for the assessment of exposure to parabens in antiperspirants.

Martins I, Lambert M, Souza Pereira A, de Faria H, de Lima E, Pereira G Environ Sci Pollut Res Int. 2019; 27(4):4219-4226.

PMID: 31828701 DOI: 10.1007/s11356-019-07038-1.


Novel MIPs-Parabens based SPE Stationary Phases Characterization and Application.

Tartaglia A, Kabir A, Ulusoy S, Ulusoy H, Merone G, Savini F Molecules. 2019; 24(18).

PMID: 31540217 PMC: 6767171. DOI: 10.3390/molecules24183334.