» Articles » PMID: 19904337

Real-time Polarization-sensitive Optical Coherence Tomography Data Processing with Parallel Computing

Overview
Journal Appl Opt
Date 2009 Nov 12
PMID 19904337
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

With the increase of the A-line speed of optical coherence tomography (OCT) systems, real-time processing of acquired data has become a bottleneck. The shared-memory parallel computing technique is used to process OCT data in real time. The real-time processing power of a quad-core personal computer (PC) is analyzed. It is shown that the quad-core PC could provide real-time OCT data processing ability of more than 80 K A-lines per second. A real-time, fiber-based, swept source polarization-sensitive OCT system with 20 K A-line speed is demonstrated with this technique. The real-time 2D and 3D polarization-sensitive imaging of chicken muscle and pig tendon is also demonstrated.

Citing Articles

Differentiation of ex vivo human breast tissue using polarization-sensitive optical coherence tomography.

South F, Chaney E, Marjanovic M, Adie S, Boppart S Biomed Opt Express. 2014; 5(10):3417-26.

PMID: 25360360 PMC: 4206312. DOI: 10.1364/BOE.5.003417.


Spectral domain optical coherence tomography of multi-MHz A-scan rates at 1310 nm range and real-time 4D-display up to 41 volumes/second.

Choi D, Hiro-Oka H, Shimizu K, Ohbayashi K Biomed Opt Express. 2012; 3(12):3067-86.

PMID: 23243560 PMC: 3521307. DOI: 10.1364/BOE.3.003067.


Swept source/Fourier domain polarization sensitive optical coherence tomography with a passive polarization delay unit.

Baumann B, Choi W, Potsaid B, Huang D, Duker J, Fujimoto J Opt Express. 2012; 20(9):10229-41.

PMID: 22535114 PMC: 3366588. DOI: 10.1364/OE.20.010229.


Polarization-maintaining buffered Fourier domain mode-locked swept source for optical coherence tomography.

Zhang J, Jing J, Wang P, Chen Z Opt Lett. 2011; 36(24):4788-90.

PMID: 22179884 PMC: 3337216. DOI: 10.1364/OL.36.004788.


Real-time bulk-motion-correction free Doppler variance optical coherence tomography for choroidal capillary vasculature imaging.

Liu G, Qi W, Yu L, Chen Z Opt Express. 2011; 19(4):3657-66.

PMID: 21369191 PMC: 3110778. DOI: 10.1364/OE.19.003657.


References
1.
Saxer C, de Boer J, Park B, Zhao Y, Chen Z, Nelson J . High-speed fiber based polarization-sensitive optical coherence tomography of in vivo human skin. Opt Lett. 2007; 25(18):1355-7. DOI: 10.1364/ol.25.001355. View

2.
Dave D, Akkin T, Milner T . Polarization-maintaining fiber-based optical low-coherence reflectometer for characterization and ranging of birefringence. Opt Lett. 2003; 28(19):1775-7. DOI: 10.1364/ol.28.001775. View

3.
Ustun T, Iftimia N, Ferguson R, Hammer D . Real-time processing for Fourier domain optical coherence tomography using a field programmable gate array. Rev Sci Instrum. 2008; 79(11):114301. PMC: 2678783. DOI: 10.1063/1.3005996. View

4.
Nassif N, Cense B, Park B, Pierce M, Yun S, Bouma B . In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve. Opt Express. 2009; 12(3):367-76. DOI: 10.1364/opex.12.000367. View

5.
Park B, Pierce M, Cense B, de Boer J . Real-time multi-functional optical coherence tomography. Opt Express. 2009; 11(7):782-93. DOI: 10.1364/oe.11.000782. View