Objective: To compare the diagnostic performance of a new dedicated ultrafast solid-state cardiac camera (Discovery NM 530c [DNM]) with standard dual detector cameras (S-SPECT) in myocardial perfusion imaging. The primary goal was a per-patient analysis of diagnostic performance of the DNM using S-SPECT as the reference standard.

Methods And Results: In total, 168 patients underwent one-day Tc-99m tetrofosmin rest/stress myocardial perfusion SPECT. DNM and S-SPECT images were obtained with the same injected doses. The DNM camera uses an array of cadmium zinc telluride pixilated detectors and a multipinhole collimator simultaneously imaging all cardiac views with no moving parts. Rest and stress acquisition times were 4 and 2 minutes for DNM and 14 and 12 minutes for S-SPECT. Two blinded readers independently interpreted all scans on a patient level and on a vascular territory level using a standard five-point scale. Interobserver differences were resolved by a third observer. Agreement between DNM and S-SPECT for presence or absence of myocardial perfusion defects on a per-patient analysis was 91.9% and 92.5%, respectively. Correlation coefficients of rest and stress left ventricular ejection fractions were 0.87 (P < .01) and 0.90 (P < .01).

Conclusion: The diagnostic performance of DNM is comparable to that of S-SPECT on a per-patient basis. However, superior image quality can be achieved with significantly shorter acquisition times with DNM because of improved count sensitivity and image contrast over S-SPECT.

Citing Articles

New Generation SPECT Cameras Based on Cadmium-Zinc Telluriide Technology.

Matsunari I Ann Nucl Cardiol. 2024; 10(1):59-63.

PMID: 39635329 PMC: 11612397. DOI: 10.17996/anc.24-00011.


Prognostic value of myocardial perfusion imaging by cadmium zinc telluride single-photon emission computed tomography in patients with suspected or known coronary artery disease: a systematic review and meta-analysis.

Assante R, Zampella E, Cantoni V, Green R, DAntonio A, Mannarino T Eur J Nucl Med Mol Imaging. 2023; 50(12):3647-3658.

PMID: 37480369 PMC: 10547640. DOI: 10.1007/s00259-023-06344-8.


Performance evaluation of a novel multi-pinhole collimator on triple-NaI-detector SPECT/CT for dedicated myocardial imaging.

Krizsan A, Kukuts K, Al-Muhanna W, Szoboszlai Z, Balazs L, Szabo B EJNMMI Phys. 2023; 10(1):24.

PMID: 36964406 PMC: 10039219. DOI: 10.1186/s40658-023-00541-y.


Early detection of cancer therapy cardiotoxicity by radionuclide angiography: An update.

Valzania C, Paccagnella A, Spadotto A, Ruotolo I, Bonfiglioli R, Fallani F J Nucl Cardiol. 2023; 30(5):2104-2111.

PMID: 36855007 DOI: 10.1007/s12350-023-03202-w.


Quality metrics for single-photon emission computed tomography myocardial perfusion imaging: an ASNC information statement.

Hage F, Einstein A, Ananthasubramaniam K, Bourque J, Case J, DePuey E J Nucl Cardiol. 2023; 30(2):864-907.

PMID: 36607538 DOI: 10.1007/s12350-022-03162-7.


References
1.
Faber T, Cooke C, Folks R, Vansant J, Nichols K, DePuey E . Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method. J Nucl Med. 1999; 40(4):650-9. View

2.
Steele P, Kirch D, Koss J . Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease. J Nucl Med. 2008; 49(7):1080-9. DOI: 10.2967/jnumed.107.040915. View

3.
Hansen C, Goldstein R, Akinboboye O, Berman D, Botvinick E, Churchwell K . Myocardial perfusion and function: single photon emission computed tomography. J Nucl Cardiol. 2007; 14(6):e39-60. DOI: 10.1016/j.nuclcard.2007.09.023. View

4.
Funk T, Despres P, Barber W, Shah K, Hasegawa B . A multipinhole small animal SPECT system with submillimeter spatial resolution. Med Phys. 2006; 33(5):1259-68. DOI: 10.1118/1.2190332. View

5.
Berman D, Kang X, Tamarappoo B, Wolak A, Hayes S, Nakazato R . Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging. 2009; 2(3):273-82. DOI: 10.1016/j.jcmg.2008.12.012. View