Adaptive Optics Flood-illumination Camera for High Speed Retinal Imaging

Overview
Journal Opt Express
Date 2009 Jun 12
PMID 19516608
Citations 65
Authors
Affiliations
Soon will be listed here.
Abstract

Current adaptive optics flood-illumination retina cameras operate at low frame rates, acquiring retinal images below seven Hz, which restricts their research and clinical utility. Here we investigate a novel bench top flood-illumination camera that achieves significantly higher frame rates using strobing fiber-coupled superluminescent and laser diodes in conjunction with a scientific-grade CCD. Source strength was sufficient to obviate frame averaging, even for exposures as short as 1/3 msec. Continuous frame rates of 10, 30, and 60 Hz were achieved for imaging 1.8,0.8, and 0.4 deg retinal patches, respectively. Short-burst imaging up to 500 Hz was also achieved by temporarily storing sequences of images on the CCD. High frame rates, short exposure durations (1 msec), and correction of the most significant aberrations of the eye were found necessary for individuating retinal blood cells and directly measuring cellular flow in capillaries. Cone videos of dark adapted eyes showed a surprisingly rapid fluctuation (~1 Hz) in the reflectance of single cones. As further demonstration of the value of the camera, we evaluated the tradeoff between exposure duration and image blur associated with retina motion.

Citing Articles

A parafoveal retinal cones analysis using adaptive-optics retinal camera in patients with primary open angle glaucoma.

Trolli E, Roda M, Valsecchi N, Cacciatore D, Nardi E, Della Pasqua V Eye (Lond). 2024; 38(15):2932-2938.

PMID: 39223247 PMC: 11461485. DOI: 10.1038/s41433-024-03191-1.


Automatic montaging of adaptive optics SLO retinal images based on graph theory.

Luo T, Gilbert R, Sapoznik K, Walker B, Burns S Biomed Opt Express. 2024; 15(2):1021-1037.

PMID: 38404321 PMC: 10890876. DOI: 10.1364/BOE.505013.


Programmable, high-speed, adaptive optics partially confocal multi-spot ophthalmoscope using a digital micromirror device.

Lee S, Choi S, Meleppat R, Zawadzki R, Doble N Opt Lett. 2023; 48(3):791-794.

PMID: 36723590 PMC: 10422682. DOI: 10.1364/OL.480688.


Wide-Field Three-Dimensional Depth-Invariant Cellular-Resolution Imaging of the Human Retina.

Lee B, Jeong S, Lee J, Kim T, Braaf B, Vakoc B Small. 2023; 19(11):e2203357.

PMID: 36642824 PMC: 10023497. DOI: 10.1002/smll.202203357.


Assessment of photoreceptor function with ultrafast retinal densitometry.

Bedggood P, Britten-Jones A, Ayton L, Metha A Biomed Opt Express. 2022; 13(10):5311-5326.

PMID: 36425640 PMC: 9664880. DOI: 10.1364/BOE.472174.