Conebeam CT of the Head and Neck, Part 2: Clinical Applications

Overview
Specialty Neurology
Date 2009 May 23
PMID 19461061
Citations 101
Authors
Affiliations
Soon will be listed here.
Abstract

Conebeam x-ray CT (CBCT) is being increasingly used for point-of-service head and neck and dentomaxillofacial imaging. This technique provides relatively high isotropic spatial resolution of osseous structures with a reduced radiation dose compared with conventional CT scans. In this second installment in a 2-part review, the clinical applications in the dentomaxillofacial and head and neck regions will be explored, with particular emphasis on diagnostic imaging of the sinuses, temporal bone, and craniofacial structures. Several controversies surrounding the emergence of CBCT technology will also be addressed.

Citing Articles

Evaluation of the effects of bisphosphonate therapy on the temporomandibular joint using cone beam computed tomography.

Sancar B, Gok R, Tunc S Oral Radiol. 2025; .

PMID: 40072733 DOI: 10.1007/s11282-025-00816-3.


Sex and Population Variations in Nasopalatine Canal Dimensions: A CBCT-Based Systematic Review.

Alhumaidi A, Okshah A, Al Moaleem M, Alsabi M, Muharraq I, Asiri A Med Sci Monit. 2024; 30:e945949.

PMID: 39410677 PMC: 11493316. DOI: 10.12659/MSM.945949.


Beyond the otoscope: an imaging review of congenital cholesteatoma.

Vangrinsven G, Bernaerts A, Deckers F, van Dinther J, Zarowski A, De Foer B Insights Imaging. 2024; 15(1):194.

PMID: 39112725 PMC: 11306902. DOI: 10.1186/s13244-024-01761-1.


Morphological and Dimensional Analysis of the Nasopalatine Canal: Insights from Cone-Beam Computed Tomography Imaging in a Large Cohort.

Alhumaidi A, Ahmed Aseri A, Alahmari M, Adawi H, Aldhorae K, Gadah T Med Sci Monit. 2024; 30:e944424.

PMID: 38870101 PMC: 11184986. DOI: 10.12659/MSM.944424.


Repetition Rate of Scanning Due to Motion Artefacts in Cone-Beam Computed Tomography: a Retrospective Study.

Kalabalik F, Aytugar E, Aykanat F, Ciftci C J Oral Maxillofac Res. 2024; 15(1):e6.

PMID: 38812948 PMC: 11131378. DOI: 10.5037/jomr.2024.15106.


References
1.
Dalchow C, Weber A, Bien S, Yanagihara N, Werner J . Value of digital volume tomography in patients with conductive hearing loss. Eur Arch Otorhinolaryngol. 2005; 263(2):92-9. DOI: 10.1007/s00405-005-0995-1. View

2.
Harvey R, Goddard J, Wise S, Schlosser R . Effects of endoscopic sinus surgery and delivery device on cadaver sinus irrigation. Otolaryngol Head Neck Surg. 2008; 139(1):137-42. DOI: 10.1016/j.otohns.2008.04.020. View

3.
Bachar G, Siewerdsen J, Daly M, Jaffray D, Irish J . Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery. Med Phys. 2008; 34(12):4664-77. DOI: 10.1118/1.2799492. View

4.
Brooks S, Brand J, Gibbs S, Hollender L, Lurie A, Omnell K . Imaging of the temporomandibular joint: a position paper of the American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997; 83(5):609-18. DOI: 10.1016/s1079-2104(97)90128-1. View

5.
Aschendorff A, Kubalek R, Turowski B, Zanella F, Hochmuth A, Schumacher M . Quality control after cochlear implant surgery by means of rotational tomography. Otol Neurotol. 2005; 26(1):34-7. DOI: 10.1097/00129492-200501000-00007. View