» Articles » PMID: 18096538

Individual Kidney Blood Flow Measured with Contrast-enhanced First-pass Perfusion MR Imaging

Overview
Journal Radiology
Specialty Radiology
Date 2007 Dec 22
PMID 18096538
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Unlabelled: The study design was HIPAA-compliant and approved by the Institutional Review Board, with all participants providing signed informed consent prior to the study. The purpose of this study was to prospectively evaluate the feasibility of determining renal blood flow (RBF) by using a technique based on intravenous administration of gadolinium chelate and evaluation of first-pass gadolinium chelate perfusion by using highly accelerated three-dimensional (3D) gradient-echo magnetic resonance (MR) imaging of the kidney in freely breathing subjects. Flow is determined with Kety-Schmidt formalism by modeling the uptake of gadolinium chelate in the kidney prior to its leaving through the venous system. Validation of the gadolinium chelate perfusion technique is based on comparison of values determined for participants with phase-contrast gradient-echo imaging. The model fit to the measured data is excellent over the first 7-8 seconds of gadolinium chelate uptake and diverges after its appearance in the renal vein. The perfusion data analysis technique showed less than 10% interobserver variation. The average difference between phase-contrast and gadolinium chelate perfusion measurements was 0.08 mL/sec (95% confidence interval: -3.73, 3.58) for left and right kidneys. This study demonstrates feasibility of the gadolinium chelate perfusion method for RBF measurement and discusses potential applications.

Supplemental Material: http://radiology.rsnajnls.org/cgi/content/full/246/1/241/DC1.

Citing Articles

Optimisation of ultrasound liver perfusion through a digital reference object and analysis tool.

Alberich-Bayarri A, Tomas-Cucarella J, Torregrosa-Lloret A, Saiz Rodriguez J, Marti-Bonmati L Eur Radiol Exp. 2019; 3(1):15.

PMID: 30945029 PMC: 6447630. DOI: 10.1186/s41747-019-0086-5.


Renal plasma flow (RPF) measured with multiple-inversion-time arterial spin labeling (ASL) and tracer kinetic analysis: Validation against a dynamic contrast-enhancement method.

Conlin C, Oesingmann N, Bolster Jr B, Huang Y, Lee V, Zhang J Magn Reson Imaging. 2016; 37:51-55.

PMID: 27864008 PMC: 5316347. DOI: 10.1016/j.mri.2016.11.010.


Kinetic Curve Type Assessment for Classification of Breast Lesions Using Dynamic Contrast-Enhanced MR Imaging.

Yang S, Li F, Chen J, Zhang G, Liao Y, Huang T PLoS One. 2016; 11(4):e0152827.

PMID: 27055113 PMC: 4824432. DOI: 10.1371/journal.pone.0152827.


Functional assessment of transplanted kidneys with magnetic resonance imaging.

Wang Y, Li Y, Yin L, Pu H, Chen J World J Radiol. 2015; 7(10):343-9.

PMID: 26516431 PMC: 4620115. DOI: 10.4329/wjr.v7.i10.343.


Assessing renal function in children with hydronephrosis - additional feature of MR urography.

Hadjidekov G, Hadjidekova S, Tonchev Z, Bakalova R, Aoki I Radiol Oncol. 2012; 45(4):248-58.

PMID: 22933962 PMC: 3423747. DOI: 10.2478/v10019-011-0038-z.