Doses to Critical Organs Following Radiotherapy and Concomitant Imaging of the Larynx and Breast

Overview
Journal Br J Radiol
Specialty Radiology
Date 2007 Dec 11
PMID 18065644
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

The development of conformal radiotherapy carries with it the implication of an increased number of imaging procedures at various stages throughout the overall treatment, principally for verification at some, or all, of the treatment fractions. This raises the issue of the balance between the benefit of these additional imaging exposures and the associated risk of radiocarcinogenesis arising from them. As such, it is necessary to appreciate the doses to critical organs for which individual carcinogenic risks have been estimated. In this study, doses to these organs have been measured with lithium fluoride thermoluminescence dosimetry loaded in anthropomorphic phantoms and subjected to realistic radiotherapy treatments of the larynx and breast, including concomitant CT and electronic portal imaging exposures associated with localization and verification of these treatments. Even for large numbers of concomitant images of either modality, arising from imaging at every fraction, the leakage and scatter from the radiotherapy itself is shown to dominate the overall organ dose, with imaging procedures generally contributing 5-20% of the total organ dose.

Citing Articles

Doses delivered by portal imaging quality assurance in routine practice of adjuvant breast radiotherapy worth to by monitored and compensated in some cases.

Kefs S, Giraud J, Naud J, Henry I, Gabelle-Flandin I, Balosso J Quant Imaging Med Surg. 2021; 11(8):3481-3493.

PMID: 34341725 PMC: 8245967. DOI: 10.21037/qims-19-1031.


Development of clinical application program for radiotherapy induced cancer risk calculation using Monte Carlo engine in volumetric-modulated arc therapy.

Kang D, Shin Y, Jeong S, Jung J, Lee H, Lee B Radiat Oncol. 2021; 16(1):108.

PMID: 34118968 PMC: 8199704. DOI: 10.1186/s13014-020-01722-0.


Establishment of national diagnostic reference levels (DRLs) for radiotherapy localisation computer tomography of the head and neck.

Clerkin C, Brennan S, Mullaney L Rep Pract Oncol Radiother. 2018; 23(5):407-412.

PMID: 30190653 PMC: 6107902. DOI: 10.1016/j.rpor.2018.07.012.


Radiation induced secondary malignancies: a review article.

Dracham C, Shankar A, Madan R Radiat Oncol J. 2018; 36(2):85-94.

PMID: 29983028 PMC: 6074073. DOI: 10.3857/roj.2018.00290.


Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy.

Batumalai V, Phan P, Choong C, Holloway L, Delaney G J Med Radiat Sci. 2016; 63(4):224-231.

PMID: 27741383 PMC: 5167282. DOI: 10.1002/jmrs.180.