» Articles » PMID: 17907430

Arthroscopic Lens Distortion Correction Applied to Dynamic Cartilage Loading

Overview
Journal Iowa Orthop J
Specialty Orthopedics
Date 2007 Oct 3
PMID 17907430
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

It is difficult to study the deformation of articular cartilage because it is an inhomogenous material with depth dependent constituents. In many experimental studies, cartilage is assumed to behave homogeneously and is subjected to only static or quasi-static loads. In this study, a thick walled, mechanically active culture device (TRIAX) was used to apply cyclic loading to cartilage explants at physiological stress levels. An arthroscope was fitted into the wall of the TRIAX to monitorand record the cyclic compressive behavior of the cartilage and to measure depth dependent cartilage strains. A common concern with arthroscopy systems is that the images obtained are radially distorted about a central point ("fisheye" view); therefore it is necessary to correct this distortion in order to accurately quantify distances between objects within the images. To do this, an algorithm was developed which used a calibration pattern to create an image transform. Digital video of the cyclic cartilage compression was recorded, and the distortion algorithm was applied to the images to measure the cartilage as it deformed. This technique will provide valuable and practical insight into cartilage mechanics and viability (via calcein AM-stained chondrocytes) during multiday cyclic loading of living cartilage explants. The implementation of an arthroscopy system provides the advantage of bringing microscope-level resolution into a cartilage compression device to allow for digital visualization of the entire explant at the whole-tissue level.

Citing Articles

A biological extract of turmeric (Curcuma longa) modulates response of cartilage explants to lipopolysaccharide.

Pearson W, Kott L BMC Complement Altern Med. 2019; 19(1):252.

PMID: 31506082 PMC: 6737590. DOI: 10.1186/s12906-019-2660-z.


Arthroscopic image distortion-part I: the effect of lens and viewing angles in a 2-dimensional in vitro model.

Hoshino Y, Rothrauff B, Hensler D, Fu F, Musahl V Knee Surg Sports Traumatol Arthrosc. 2014; 24(6):2065-71.

PMID: 25246178 DOI: 10.1007/s00167-014-3336-3.


Measurements of knee morphometrics using MRI and arthroscopy: a comparative study between ACL-injured and non-injured subjects.

Vrooijink S, Wolters F, Van Eck C, Fu F Knee Surg Sports Traumatol Arthrosc. 2011; 19 Suppl 1:S12-6.

PMID: 21472470 DOI: 10.1007/s00167-011-1502-4.

References
1.
Shepherd D, Seedhom B . A technique for measuring the compressive modulus of articular cartilage under physiological loading rates with preliminary results. Proc Inst Mech Eng H. 1997; 211(2):155-65. DOI: 10.1243/0954411971534278. View

2.
Shepherd D, Seedhom B . The 'instantaneous' compressive modulus of human articular cartilage in joints of the lower limb. Rheumatology (Oxford). 1999; 38(2):124-32. DOI: 10.1093/rheumatology/38.2.124. View

3.
Neu C, Hull M, Walton J . Heterogeneous three-dimensional strain fields during unconfined cyclic compression in bovine articular cartilage explants. J Orthop Res. 2005; 23(6):1390-8. DOI: 10.1016/j.orthres.2005.03.022.1100230622. View

4.
Davis M, Khotanzad A, Flamig D, Harms S . A physics-based coordinate transformation for 3-D image matching. IEEE Trans Med Imaging. 1997; 16(3):317-28. DOI: 10.1109/42.585766. View

5.
Jurvelin J, Buschmann M, Hunziker E . Optical and mechanical determination of Poisson's ratio of adult bovine humeral articular cartilage. J Biomech. 1997; 30(3):235-41. DOI: 10.1016/s0021-9290(96)00133-9. View