» Articles » PMID: 11425068

Depth- and Strain-dependent Mechanical and Electromechanical Properties of Full-thickness Bovine Articular Cartilage in Confined Compression

Overview
Journal J Biomech
Specialty Physiology
Date 2001 Jun 27
PMID 11425068
Citations 80
Authors
Affiliations
Soon will be listed here.
Abstract

Compression tests have often been performed to assess the biomechanical properties of full-thickness articular cartilage. We tested whether the apparent homogeneous strain-dependent properties, deduced from such tests, reflect both strain- and depth-dependent material properties. Full-thickness bovine articular cartilage was tested by oscillatory confined compression superimposed on a static offset up to 45%. and the data fit to estimate modulus, permeability, and electrokinetic coefficient assuming homogeneity. Additional tests on partial-thickness cartilage were then performed to assess depth- and strain-dependent properties in an inhomogeneous model, assuming three discrete layers (i = 1 starting from the articular surface, to i = 3 up to the subchondral bone). Estimates of the zero-strain equilibrium confined compression modulus (H(A0)), the zero-strain permeability (kp0) and deformation dependence constant (M), and the deformation-dependent electrokinetic coefficient (ke) differed among individual layers of cartilage and full-thickness cartilage. HiA0 increased from layer 1 to 3 (0.27 to 0.71 MPa), and bracketed the apparent homogeneous value (0.47 MPa). ki(p0) decreased from layer 1 to 3 (4.6 x 10(-15) to 0.50 x 10(-15) m2/Pa s) and was less than the homogeneous value (7.3 x 10(-15) m2/Pa s), while Mi increased from layer 1 to 3 (5.5 to 7.4) and became similar to the homogeneous value (8.4). The amplitude of ki(e) increased markedly with compressive strain, as did the homogeneous value: at low strain, it was lowest near the articular surface and increased to a peak in the middle-deep region. These results help to interpret the biomechanical assessment of full-thickness articular cartilage.

Citing Articles

Engineering Tough and Elastic Polyvinyl Alcohol-Based Hydrogel with Antimicrobial Properties.

Baidya A, Budiman A, Jain S, Oz Y, Annabi N Adv Nanobiomed Res. 2024; 4(9).

PMID: 39650171 PMC: 11620288. DOI: 10.1002/anbr.202300173.


Use of Hydrogels in Regenerative Medicine: Focus on Mechanical Properties.

Carton F, Rizzi M, Canciani E, Sieve G, Di Francesco D, Casarella S Int J Mol Sci. 2024; 25(21).

PMID: 39518979 PMC: 11545898. DOI: 10.3390/ijms252111426.


In Situ Loading and Time-Resolved Synchrotron-Based Phase Contrast Tomography for the Mechanical Investigation of Connective Knee Tissues: A Proof-of-Concept Study.

Dejea H, Pierantoni M, Orozco G, B Wrammerfors E, Gstohl S, Schleputz C Adv Sci (Weinh). 2024; 11(21):e2308811.

PMID: 38520713 PMC: 11151037. DOI: 10.1002/advs.202308811.


Polarimetric second harmonic generation microscopy of partially oriented fibers II: Imaging study.

Alizadeh M, Habach F, Maciulis M, Kontenis L, Bagdonas S, Krouglov S Biophys J. 2023; 122(19):3937-3949.

PMID: 37621088 PMC: 10560685. DOI: 10.1016/j.bpj.2023.08.015.


Effect of knee joint loading on chondrocyte mechano-vulnerability and severity of post-traumatic osteoarthritis induced by ACL-injury in mice.

Kotelsky A, Elahi A, Nejat Yigit C, Proctor A, Mannava S, Proschel C Osteoarthr Cartil Open. 2022; 4(1):100227.