» Articles » PMID: 17326089

R2* Imaging of Transfusional Iron Burden at 3T and Comparison with 1.5T

Overview
Date 2007 Feb 28
PMID 17326089
Citations 69
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To determine normative R2* values in the liver and heart at 3T, and establish the relationship between R2* at 3T and 1.5T over a range of tissue iron concentrations.

Materials And Methods: A total of 20 healthy control subjects and 14 transfusion-dependent patients were scanned at 1.5T and 3T. At each field strength R2* imaging was performed in the liver and heart.

Results: Normative R2* values in the liver were estimated from the control group to be 39.2 +/- 9.0 second(-1) at 1.5T and 69.1 +/- 21.9 second(-1) at 3T. Normative cardiac values were estimated as 23.4 +/- 2.2 second(-1) at 1.5T and 30.0 +/- 3.7 second(-1) at 3T. The combined R2* data from patients and control subjects exhibited a linear relationship between 3T and 1.5T. In the liver, the line of best fit to the 3T vs. 1.5T data had a slope of 2.00 +/- 0.06 and an intercept of -11 +/- 4 second(-1). In the heart, it had a slope of 1.88 +/- 0.14 and an intercept of -15 +/- 4 second(-1).

Conclusion: These preliminary data suggest that the iron-dependent component of R2* scales linearly with field strength over a wide range of tissue iron concentrations. The incidence of susceptibility artifacts may, however, also increase with field strength.

Citing Articles

Preliminary quantitative analysis of renal sinus fat dysfunction in T2DM patients using MRI fat fraction and R2* mapping.

Dong Y, Zhang Q, Wang X, Liu Y, An Q, Zhang Z Front Endocrinol (Lausanne). 2025; 16:1486839.

PMID: 40046878 PMC: 11880264. DOI: 10.3389/fendo.2025.1486839.


Diagnostic Value of T1 Mapping in Detecting Iron Overload in Indian Patients with Thalassemia Major: A Comparison with T2* Mapping.

Singh S, Jagia P, Ojha V, Seth T, Naik N, Ganga K Indian J Radiol Imaging. 2023; 34(1):54-59.

PMID: 38106847 PMC: 10723946. DOI: 10.1055/s-0043-1772467.


Magnetic resonance imaging assessment of the changes of cardiac and hepatic iron load in thalassemia patients before and after hematopoietic stem cell transplantation.

Xu F, Li D, Tang C, Liang B, Guan K, Liu R Sci Rep. 2023; 13(1):19652.

PMID: 37950037 PMC: 10638442. DOI: 10.1038/s41598-023-46524-y.


Simulation of a virtual liver iron overload model and R * estimation using multispectral fat-water models for GRE and UTE acquisitions at 1.5 T and 3 T.

Neupane P, Shrestha U, Brasher S, Abramson Z, Tipirneni-Sajja A NMR Biomed. 2023; 36(12):e5018.

PMID: 37539770 PMC: 10838367. DOI: 10.1002/nbm.5018.


The Evaluation of Renal Iron Deposition With a 3 Tesla MRI Device in Beta-Thalassemia Major Patients.

Guzelbey T, Demirbas Z, Gurses B Cureus. 2023; 15(3):e36179.

PMID: 37065363 PMC: 10103619. DOI: 10.7759/cureus.36179.


References
1.
Alexopoulou E, Stripeli F, Baras P, Seimenis I, Kattamis A, Ladis V . R2 relaxometry with MRI for the quantification of tissue iron overload in beta-thalassemic patients. J Magn Reson Imaging. 2005; 23(2):163-70. DOI: 10.1002/jmri.20489. View

2.
Tumkur S, Vu A, Li L, Prasad P . Evaluation of intrarenal oxygenation at 3.0 T using 3-dimensional multiple gradient-recalled echo sequence. Invest Radiol. 2006; 41(2):181-4. PMC: 2915892. DOI: 10.1097/01.rli.0000187166.43871.fb. View

3.
Atalay M, Poncelet B, KANTOR H, Brady T, Weisskoff R . Cardiac susceptibility artifacts arising from the heart-lung interface. Magn Reson Med. 2001; 45(2):341-5. DOI: 10.1002/1522-2594(200102)45:2<341::aid-mrm1043>3.0.co;2-q. View

4.
Anderson L, Holden S, Davis B, Prescott E, Charrier C, Bunce N . Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur Heart J. 2002; 22(23):2171-9. DOI: 10.1053/euhj.2001.2822. View

5.
An H, Lin W . Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: effects of magnetic field variation. Magn Reson Med. 2002; 47(5):958-66. DOI: 10.1002/mrm.10148. View