Consistent Non-cartesian Off-axis MRI Quality: Calibrating and Removing Multiple Sources of Demodulation Phase Errors
Overview
Affiliations
The consistency of off-axis MRI with non-Cartesian sequences across a large number of scanners is highly variable. Improper timing alignment of the gradient fields, data acquisition system, and real-time frequency demodulation reference signal, which are necessary for off-axis imaging, is an important source of this variability. In addition, eddy currents and anisotropic gradient delays cause deviations in k-space trajectories that in turn make the demodulation reference signals inaccurate. A method is presented to quickly measure the timing error in the frequency demodulation reference signal and separate it from anisotropic gradient delays. k-Space deviations, as measured with a previous gradient calibration technique, are shown to be a second source of demodulation phase errors that degrade image quality. Using the timing delay and k-space deviations, a retrospective phase correction is applied to each k-space sample before the data are regridded during reconstruction. The timing delays of four MR scanners were measured to be 4.2-7.5 micros below the manufacturer's suggested delay. Significant degradation in 3D radial (3D projection reconstruction (PR)) knee and breast images are retrospectively corrected while a partial prospective correction is applied for spiral imaging. The method allows for more consistent performance of non-Cartesian sequences across multiple scanners without operator intervention.
Lee N, Ramasawmy R, Lim Y, Campbell-Washburn A, Nayak K Magn Reson Med. 2022; 88(2):691-710.
PMID: 35445768 PMC: 9232904. DOI: 10.1002/mrm.29232.
Impact of gradient imperfections on bone water quantification with UTE MRI.
Zhao X, Lee H, Song H, Cheng C, Wehrli F Magn Reson Med. 2020; 84(4):2034-2047.
PMID: 32307749 PMC: 7348668. DOI: 10.1002/mrm.28272.
Variable density incoherent spatiotemporal acquisition (VISTA) for highly accelerated cardiac MRI.
Ahmad R, Xue H, Giri S, Ding Y, Craft J, Simonetti O Magn Reson Med. 2014; 74(5):1266-78.
PMID: 25385540 PMC: 4556611. DOI: 10.1002/mrm.25507.
Corum C, Benson J, Idiyatullin D, Snyder A, Snyder C, Hutter D Radiology. 2014; 274(2):540-7.
PMID: 25247405 PMC: 4314289. DOI: 10.1148/radiol.14131273.
High-resolution 3D radial bSSFP with IDEAL.
Moran C, Brodsky E, Henze Bancroft L, Reeder S, Yu H, Kijowski R Magn Reson Med. 2013; 71(1):95-104.
PMID: 23504943 PMC: 3762898. DOI: 10.1002/mrm.24633.