Abstract

Purpose: To improve the slice profile and image quality of R2* mapping in the iceball during cryoablation with ultrashort echo time (UTE) imaging by compensating for eddy currents induced by the selective gradient when half-pulse radiofrequency (RF) excitation is employed to achieve UTEs.

Materials And Methods: A method to measure both B0 and linear eddy currents simultaneously is first presented. This is done with a least-square fitting process on calibration data collected on a phantom. Eddy currents during excitation are compensated by redesigning the RF pulse and the selective gradient accordingly, while that resultant from the readout gradient are compensated for during image reconstruction. In vivo data were obtained continuously during the cryoablation experiments to calculate the R2* values in the iceball and to correlate them with the freezing process.

Results: Image quality degradation due to eddy currents is significantly reduced with the proposed approaches. R2* maps of iceball throughout the cryoablation experiments were achieved with improved quality.

Conclusion: The proposed approaches are effective for compensating eddy currents during half-pulse RF excitation as well as readout. TEs as short as 100 microsec were obtained, allowing R2* maps to be obtained from frozen tissues with improved quality.

Citing Articles

Making the invisible visible-ultrashort echo time magnetic resonance imaging: Technical developments and applications.

Ma Y, Jang H, Jerban S, Chang E, Chung C, Bydder G Appl Phys Rev. 2022; 9(4):041303.

PMID: 36467869 PMC: 9677812. DOI: 10.1063/5.0086459.


Fast bound and pore water mapping of cortical bone with arbitrary slice oriented two-dimensional ultra-short echo time.

Harkins K, Ketsiri T, Nyman J, Does M Magn Reson Med. 2022; 89(2):767-773.

PMID: 36226656 PMC: 9897494. DOI: 10.1002/mrm.29484.


High-contrast osteochondral junction imaging using a 3D dual adiabatic inversion recovery-prepared ultrashort echo time cones sequence.

Lombardi A, Jang H, Wei Z, Jerban S, Wallace M, Masuda K NMR Biomed. 2021; 34(8):e4559.

PMID: 34021649 PMC: 8254801. DOI: 10.1002/nbm.4559.


Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model.

Kim D, Hwang K, Kim H, Cha J, Jang H, Park J Korean J Radiol. 2021; 22(5):782-791.

PMID: 33660460 PMC: 8076835. DOI: 10.3348/kjr.2020.0640.


Magnetic Resonance-Guided Prostate Ablation.

Woodrum D, Kawashima A, Gorny K, Mynderse L Semin Intervent Radiol. 2019; 36(5):351-366.

PMID: 31798208 PMC: 6887527. DOI: 10.1055/s-0039-1697001.


References
1.
Jung Y, Jashnani Y, Kijowski R, Block W . Consistent non-cartesian off-axis MRI quality: calibrating and removing multiple sources of demodulation phase errors. Magn Reson Med. 2006; 57(1):206-12. DOI: 10.1002/mrm.21092. View

2.
Rahmer J, Bornert P, Groen J, Bos C . Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med. 2006; 55(5):1075-82. DOI: 10.1002/mrm.20868. View

3.
Jackson J, Meyer C, Nishimura D, Macovski A . Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. IEEE Trans Med Imaging. 1991; 10(3):473-8. DOI: 10.1109/42.97598. View

4.
Nielsen H, Gold G, Olcott E, Pauly J, Nishimura D . Ultra-short echo-time 2D time-of-flight MR angiography using a half-pulse excitation. Magn Reson Med. 1999; 41(3):591-9. DOI: 10.1002/(sici)1522-2594(199903)41:3<591::aid-mrm23>3.0.co;2-r. View

5.
Robson M, Benjamin M, Gishen P, Bydder G . Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences. Clin Radiol. 2004; 59(8):727-35. DOI: 10.1016/j.crad.2003.11.021. View