Relationship Between Noise, Dose, and Pitch in Cardiac Multi-detector Row CT

Overview
Journal Radiographics
Specialty Radiology
Date 2006 Nov 15
PMID 17102050
Citations 53
Authors
Affiliations
Soon will be listed here.
Abstract

In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution.

Citing Articles

Investigating the slice thickness effect on noise and diagnostic content of single-source multi-slice computerized axial tomography.

Abdulkareem N, Hajee S, Hassan F, Ibrahim I, Al-Khalidi R, Abdulqader N J Med Life. 2023; 16(6):862-867.

PMID: 37675166 PMC: 10478658. DOI: 10.25122/jml-2022-0188.


Clinical Feasibility of Deep Learning-Based Image Reconstruction on Coronary Computed Tomography Angiography.

Koo S, Jung Y, Um K, Kim T, Kim J, Park C J Clin Med. 2023; 12(10).

PMID: 37240607 PMC: 10219179. DOI: 10.3390/jcm12103501.


Individualized scan protocols for CT angiography: an animal study for contrast media or radiation dose optimization.

Haubold J, Zensen S, Hosch R, Schaarschmidt B, Bos D, Schmidt B Eur Radiol Exp. 2023; 7(1):24.

PMID: 37185930 PMC: 10130261. DOI: 10.1186/s41747-023-00332-1.


Data harmonisation for information fusion in digital healthcare: A state-of-the-art systematic review, meta-analysis and future research directions.

Nan Y, Del Ser J, Walsh S, Schonlieb C, Roberts M, Selby I Inf Fusion. 2022; 82:99-122.

PMID: 35664012 PMC: 8878813. DOI: 10.1016/j.inffus.2022.01.001.


Quantitative measurements of emphysema in ultra-high resolution computed tomography using model-based iterative reconstruction in comparison to that using hybrid iterative reconstruction.

Muramatsu S, Sato K, Yamashiro T, Doi K Phys Eng Sci Med. 2022; 45(1):115-124.

PMID: 35023075 DOI: 10.1007/s13246-021-01091-2.