Recent Articles
1.
Gong H, Yu L, Leng S, Hsieh S, Fletcher J, McCollough C
Med Phys . 2025 Feb; PMID: 39945452
Background: Accurate low-dose CT simulation is required to efficiently assess reconstruction and dose reduction techniques. Projection domain noise insertion requires proprietary information from manufacturers. Analytic image domain noise insertion methods...
2.
Esquivel A, Potretzke T, Ferrero A, Inoue A, Hoodeshenans S, Mileto A, et al.
Abdom Radiol (NY) . 2025 Jan; PMID: 39865183
Purpose: To compare same-day photon-counting detector CT (PCD-CT) to conventional energy-integrating detector CT (EID-CT) for detection of small renal stones (≤ 3 mm). Methods: Patients undergoing clinical dual-energy EID-CT for...
3.
Dillman J, Tkach J, Fletcher J, Bruining D, Lu A, Kugathasan S, et al.
Inflamm Bowel Dis . 2025 Jan; PMID: 39853252
Background: We previously identified circulating and MRI biomarkers associated with the surgical management of Crohn's disease (CD). Here we tested associations between these biomarkers and ileal resection inflammation and collagen...
4.
Yalon M, Mohammadinejad P, Inoue A, Takahashi H, Ehman E, Esquivel A, et al.
Abdom Radiol (NY) . 2024 Dec; PMID: 39692760
Purpose: To evaluate correlation between terminal ileal (TI) stricture diagnosis at MR enterography (MRE) and ileocolonoscopy (IC) in patients with Crohn's disease (CD). Methods: One hundred and four patients with...
5.
Lok U, Tang S, Gong P, Smyrk T, Huang C, DeRuiter R, et al.
Eur Radiol . 2024 Nov; PMID: 39547980
Objective: Ultrasound microvessel imaging (UMI) may offer noninvasive, highly sensitive microvessel imaging for assessing Crohn's disease (CD). However, a quantification metric that demonstrates a strong correlation with pathological inflammation is...
6.
El Sadaney A, Ferrero A, Rajendran K, Jasper S, Mazza G, Broski S, et al.
AJR Am J Roentgenol . 2024 Oct; 224(1):e2431909. PMID: 39475199
Spectral localizer images from photon-counting detector (PCD) CT can be used for bone mineral density (BMD) evaluation given their 2D projectional nature and material decomposition capability. As all CT examinations...
7.
Rieder F, Baker M, Bruining D, Fidler J, Ehman E, Sheedy S, et al.
Radiology . 2024 Oct; 313(1):e249020. PMID: 39470432
No abstract available.
8.
Lu C, Rosentreter R, Parker C, Remillard J, Wilson S, Baker M, et al.
Lancet Gastroenterol Hepatol . 2024 Oct; 9(12):1101-1110. PMID: 39447590
Background: Diagnostic imaging using CT enterography, magnetic resonance enterography, and intestinal ultrasound are important tools in evaluating stricturing Crohn's disease. Definitions of strictures have been developed for CT enterography and...
9.
Gress D, Samei E, Frush D, Pelzl C, Fletcher J, Mahesh M, et al.
J Am Coll Radiol . 2024 Oct; 22(1):66-75. PMID: 39427722
Objective: This study sought to determine consensus opinions from subspecialty radiologists and imaging physicists on the relative importance of image quality features in CT. Methods: A prospective survey of subspecialty...
10.
Inoue A, Diehn F, Nagelschneider A, Passe T, DeLone D, Nelson B, et al.
Acta Radiol . 2024 Oct; 65(11):1411-1421. PMID: 39415759
Background: SynthesiZed Improved Resolution and Concurrent nOise reductioN (ZIRCON) is a multi-kernel synthesis method that creates a single series of thin-slice computed tomography (CT) images displaying low noise and high...