» Articles » PMID: 16142718

Field Map Estimation with a Region Growing Scheme for Iterative 3-point Water-fat Decomposition

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2005 Sep 6
PMID 16142718
Citations 94
Authors
Affiliations
Soon will be listed here.
Abstract

Robust fat suppression techniques are required for many clinical applications. Multi-echo water-fat separation methods are relatively insensitive to B(0) field inhomogeneity compared to the fat saturation method. Estimation of this field inhomogeneity, or field map, is an essential and important step, which is well known to have ambiguity. For an iterative water-fat decomposition method recently proposed, ambiguities still exist, but are more complex in nature. They were studied by analytical expressions and simulations. To avoid convergence to incorrect field map solutions, an initial guess closer to the true field map is necessary. This can be achieved using a region growing process, which correlates the estimation among neighboring pixels. Further improvement in stability is achieved using a low-resolution reconstruction to guide the selection of the starting pixels for the region growing. The proposed method was implemented and shown to significantly improve the algorithm's immunity to field inhomogeneity.

Citing Articles

Chemical shift-encoded multishot EPI for navigator-free prostate DWI.

Dong Y, Atkinson D, Koolstra K, van Osch M, Bornert P Magn Reson Med. 2024; 93(3):1059-1076.

PMID: 39402739 PMC: 11680737. DOI: 10.1002/mrm.30334.


A Prediction Model for Detecting Dysthyroid Optic Neuropathy Based on Clinical Factors and Imaging Markers of the Optic Nerve and Cerebrospinal Fluid in the Optic Nerve Sheath.

Wu H, Luo B, Yuan G, Wang Q, Liu P, Zhao Y Curr Med Sci. 2024; 44(4):827-832.

PMID: 39096474 DOI: 10.1007/s11596-024-2890-2.


Application and research progress of magnetic resonance proton density fat fraction in metabolic dysfunction-associated steatotic liver disease: a comprehensive review.

Qi H, Jiang S, Nan J, Guo H, Cheng C, He X Abdom Radiol (NY). 2024; 50(1):185-197.

PMID: 39048719 DOI: 10.1007/s00261-024-04448-9.


Comparison of Vendor-Independent Software Tools for Liver Proton Density Fat Fraction Estimation at 1.5 T.

Zsombor Z, Zsely B, Ronaszeki A, Stollmayer R, Budai B, Palotas L Diagnostics (Basel). 2024; 14(11).

PMID: 38893664 PMC: 11171873. DOI: 10.3390/diagnostics14111138.


Theoretical and experimental study of attenuation in cancellous bone.

Xu W, Xie W, Yu D, Sun H, Gu Y, Tao X J Biomed Opt. 2024; 29(Suppl 1):S11526.

PMID: 38505736 PMC: 10949015. DOI: 10.1117/1.JBO.29.S1.S11526.