» Articles » PMID: 16084429

Assessment of Myocardial Perfusion by Dynamic N-13 Ammonia PET Imaging: Comparison of 2 Tracer Kinetic Models

Overview
Journal J Nucl Cardiol
Date 2005 Aug 9
PMID 16084429
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Measurement of myocardial blood flow (MBF) by dynamic nitrogen 13 ammonia (NH(3)) positron emission tomography (PET) uses tracer kinetic modeling to analyze time-activity curves. We compared 2 commonly used models with 2 compartments (2C) and 3 compartments (3C) for quantification of MBF and coronary flow reserve (CFR).

Methods And Results: Seventy-seven patients underwent NH(3) PET at rest and during hyperemia. Time-activity curves for blood pool and myocardial segments were obtained from short-axis images of dynamic sequences. Model fitting of the 2C and 3C models was performed to estimate regional MBF. MBF values calculated by 2C and 3C models were 0.98 +/- 0.31 mL.min(-1).g(-1) and 1.11 +/- 0.37 mL.min(-1).g(-1), respectively, at rest (P < .0001) and 2.79 +/- 1.18 mL.min(-1).g(-1) and 2.46 +/- 1.02 mL.min(-1).g(-1), respectively, during hyperemia (P < .01), resulting in a CFR of 3.02 +/- 1.31 and 2.39 +/- 1.15 (P < .0001), respectively. Significant correlation was observed between the 2 models for calculation of resting MBF (r = 0.78), hyperemic MBF (r = 0.68), and CFR (r = 0.68).

Conclusion: Measurements of MBF and CFR by 2C and 3C models are significantly related. However, quantification of MBF and CFR significantly differs between the methods. This difference needs to be considered when normal values are established or when measurements obtained with different methods need to be compared.

Citing Articles

The Influence of Kinetic Models and Attenuation Correction on Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography (CZT SPECT)-Derived Myocardial Blood Flow and Reserve: Correlation with Invasive Angiography Data.

Mochula A, Maltseva A, Kopeva K, Grakova E, Mochula O, Zavadovsky K J Clin Med. 2024; 13(5).

PMID: 38592092 PMC: 10932033. DOI: 10.3390/jcm13051271.


EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging.

Sciagra R, Lubberink M, Hyafil F, Saraste A, Slart R, Agostini D Eur J Nucl Med Mol Imaging. 2020; 48(4):1040-1069.

PMID: 33135093 PMC: 7603916. DOI: 10.1007/s00259-020-05046-9.


Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET.

Kim H, Cho S, Kim J, Kwon S, Lee B, Bom H Asia Ocean J Nucl Med Biol. 2016; 2(2):104-10.

PMID: 27408866 PMC: 4937694.


Quantification of myocardial blood flow in absolute terms using (82)Rb PET imaging: the RUBY-10 Study.

Nesterov S, Deshayes E, Sciagra R, Settimo L, Declerck J, Pan X JACC Cardiovasc Imaging. 2014; 7(11):1119-1127.

PMID: 25306543 PMC: 4260449. DOI: 10.1016/j.jcmg.2014.08.003.


Characterizing the normal range of myocardial blood flow with ⁸²rubidium and ¹³N-ammonia PET imaging.

Renaud J, DaSilva J, Beanlands R, deKemp R J Nucl Cardiol. 2013; 20(4):578-91.

PMID: 23657833 DOI: 10.1007/s12350-013-9721-3.


References
1.
Schafers K, Spinks T, Camici P, Bloomfield P, Rhodes C, Law M . Absolute quantification of myocardial blood flow with H(2)(15)O and 3-dimensional PET: an experimental validation. J Nucl Med. 2002; 43(8):1031-40. View

2.
Muzik O, Beanlands R, Wolfe E, Hutchins G, Schwaiger M . Automated region definition for cardiac nitrogen-13-ammonia PET imaging. J Nucl Med. 1993; 34(2):336-44. View

3.
Hutchins G, Schwaiger M, Rosenspire K, Krivokapich J, Schelbert H, Kuhl D . Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging. J Am Coll Cardiol. 1990; 15(5):1032-42. DOI: 10.1016/0735-1097(90)90237-j. View

4.
Muller P, Czernin J, Choi Y, Aguilar F, Nitzsche E, Buxton D . Effect of exercise supplementation during adenosine infusion on hyperemic blood flow and flow reserve. Am Heart J. 1994; 128(1):52-60. DOI: 10.1016/0002-8703(94)90009-4. View

5.
van den Hoff J, Burchert W, Borner A, Fricke H, KUHNEL G, Meyer G . [1-(11)C]Acetate as a quantitative perfusion tracer in myocardial PET. J Nucl Med. 2001; 42(8):1174-82. View