» Articles » PMID: 2805269

13N Ammonia Myocardial Imaging at Rest and with Exercise in Normal Volunteers. Quantification of Absolute Myocardial Perfusion with Dynamic Positron Emission Tomography

Overview
Journal Circulation
Date 1989 Nov 1
PMID 2805269
Citations 69
Authors
Affiliations
Soon will be listed here.
Abstract

Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided into eight sectors, and a small region of interest was assigned to the left ventricular blood pool to obtain the arterial input function. The net extraction of 13N ammonia was obtained for each sector by dividing the tissue 13N concentration at 10 minutes by the integral of the input function from the time of injection to 10 minutes. With this approach for calculating net extractions, rest and exercise net extractions were not significantly different from each other. To obviate possible overestimation of the true 13N ammonia input function by contamination by 13N-labeled compounds other than 13N ammonia or by spillover from myocardium into blood pool, the net extractions were calculated using only the first 90 seconds of the blood and tissue time-activity curves. This approach for calculating net extractions yielded significant differences between rest and exercise, with an average ratio of exercise to rest of 1.38 +/- 0.34. Nonetheless, the increase was less than predicted from the average 2.7-2.8-fold increase in double product at peak exercise or the 1.7-fold increase in double product at 1 minute after exercise. However, when the first 90 seconds of dynamic data were fit with a two compartment tracer kinetic model, average perfusion rates of 0.75 +/- 0.43 ml/min/g at rest and 1.50 +/- 0.74 ml/min/g with exercise were obtained. This average increase in perfusion of 2.2-fold corresponded to similar average increases in double product. Thus, the noninvasive technique of PET imaging with 13N ammonia shows promise for future applications in determining absolute flows in patients with coronary artery disease.

Citing Articles

Carimas: An Extensive Medical Imaging Data Processing Tool for Research.

Rainio O, Han C, Teuho J, Nesterov S, Oikonen V, Piirola S J Digit Imaging. 2023; 36(4):1885-1893.

PMID: 37106213 PMC: 10406992. DOI: 10.1007/s10278-023-00812-1.


Saudi Heart Association Guidelines on Best Practices in the Management of Chronic Coronary Syndromes.

AlShammeri O, Al Saif S, Al Shehri H, Alasng M, Qaddoura F, Al Shehri M J Saudi Heart Assoc. 2022; 34(3):182-211.

PMID: 36578770 PMC: 9762239. DOI: 10.37616/2212-5043.1320.


The Role of Positron Emission Tomography in Bariatric Surgery Research: a Review.

Bini J, Norcross M, Cheung M, Duffy A Obes Surg. 2021; 31(10):4592-4606.

PMID: 34304378 DOI: 10.1007/s11695-021-05576-7.


Determination of [N-13]-ammonia extraction fraction in patients with coronary artery disease by calibration to invasive coronary and fractional flow reserve.

Nye J, Piccinelli M, Hwang D, Cooke C, Paeng J, Lee J J Nucl Cardiol. 2021; 29(5):2210-2219.

PMID: 34036523 PMC: 10630982. DOI: 10.1007/s12350-021-02628-4.


EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging.

Sciagra R, Lubberink M, Hyafil F, Saraste A, Slart R, Agostini D Eur J Nucl Med Mol Imaging. 2020; 48(4):1040-1069.

PMID: 33135093 PMC: 7603916. DOI: 10.1007/s00259-020-05046-9.