» Articles » PMID: 2312957

Noninvasive Quantification of Regional Blood Flow in the Human Heart Using N-13 Ammonia and Dynamic Positron Emission Tomographic Imaging

Overview
Date 1990 Apr 1
PMID 2312957
Citations 152
Authors
Affiliations
Soon will be listed here.
Abstract

Evaluation of regional myocardial blood flow by conventional scintigraphic techniques is limited to the qualitative assessment of regional tracer distribution. Dynamic imaging with positron emission tomography allows the quantitative delineation of myocardial tracer kinetics and, hence, the measurement of physiologic processes such as myocardial blood flow. To test this hypothesis, positron emission tomographic imaging in combination with N-13 ammonia was performed at rest and after pharmacologically induced vasodilation in seven healthy volunteers. Myocardial and blood time-activity curves derived from regions of interest over the heart and ventricular chamber were fitted using a three compartment model for N-13 ammonia, yielding rate constants for tracer uptake and retention. Myocardial blood flow (K1) averaged 88 +/- 17 ml/min per 100 g at rest and increased to 417 +/- 112 ml/min per 100 g after dipyridamole infusion (0.56 mg/kg) and handgrip exercise. The coronary reserve averaged 4.8 +/- 1.3 and was not significantly different in the septal, anterior and lateral walls of the left ventricle. Blood flow values showed only a minor dependence on the correction for blood metabolites of N-13 ammonia. These data demonstrate that quantification of regional myocardial blood flow is feasible by dynamic positron emission tomographic imaging. The observed coronary flow reserve after dipyridamole is in close agreement with the results obtained by invasive techniques, indicating accurate flow estimates over a wide range. Thus, positron emission tomography may provide accurate and noninvasive definition of the functional significance of coronary artery disease and may allow the improved selection of patients for revascularization.

Citing Articles

Higher processing repeatability of myocardial flow reserve calculated using net retention model compared to one compartment model in SPECT studies.

Cichocki P, Plachcinska A, Blaszczyk M, Adamczewski Z Sci Rep. 2024; 14(1):16671.

PMID: 39030217 PMC: 11271556. DOI: 10.1038/s41598-024-67474-z.


Total-body dynamic PET/CT imaging reveals kinetic distribution of [N]NH in normal organs.

Liu G, Gu T, Chen S, Gu Y, Yu H, Shi H Eur J Nucl Med Mol Imaging. 2024; 51(13):3888-3899.

PMID: 38976037 DOI: 10.1007/s00259-024-06826-3.


Multimodality assessment of the coronary microvasculature with TIMI frame count versus perfusion PET highlights coronary changes characteristic of coronary microvascular disease.

Wayne N, Wu Q, Moore S, Ferrari V, Metzler S, Guerraty M Front Cardiovasc Med. 2024; 11:1395036.

PMID: 38966750 PMC: 11222597. DOI: 10.3389/fcvm.2024.1395036.


Interplay Between Systemic Inflammation, Myocardial Injury, and Coronary Microvascular Dysfunction in Rheumatoid Arthritis: Results From the LiiRA Study.

Weber B, Weisenfeld D, Massarotti E, Seyok T, Cremone G, Lam E J Am Heart Assoc. 2024; 13(9):e030387.

PMID: 38686879 PMC: 11179857. DOI: 10.1161/JAHA.123.030387.


Highlighting Fibroblasts Activation in Fibrosis: The State-of-The-Art Fibroblast Activation Protein Inhibitor PET Imaging in Cardiovascular Diseases.

Cui Y, Wang Y, Wang S, Du B, Li X, Li Y J Clin Med. 2023; 12(18).

PMID: 37762974 PMC: 10531835. DOI: 10.3390/jcm12186033.