» Articles » PMID: 15588881

Measurement of Tumor Diameter-dependent Mobility of Lung Tumors by Dynamic MRI

Overview
Journal Radiother Oncol
Specialties Oncology
Radiology
Date 2004 Dec 14
PMID 15588881
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Purpose: To assess the influence of tumor diameter on tumor mobility and motion of the tumor bearing hemithorax during the whole breathing cycle in patients with stage I non-small-cell lung cancer (NSCLC) using dynamic MRI.

Patients And Methods: Breathing cycles of thirty-nine patients with solitary NSCLCs were examined using a trueFISP sequence (three images per second). Patients were divided into three groups according to the maximal tumor diameter in the transverse plane (<3, 3-5 and >5 cm). Continuous time-distance curves and deep inspiratory and expiratory positions of the chest wall, the diaphragm and the tumor were measured in three planes. Motion of tumor-bearing and corresponding contralateral non-tumor bearing regions was compared.

Results: Patients with a tumor >3 cm showed a significantly lower diaphragmatic motion of the tumor bearing compared with the non-tumor bearing hemithorax in the craniocaudal (CC) directions (tumors 3-5 cm: 23.4+/-1.2 vs 21.1+/-1.5 cm (P<0.05); tumors >5 cm: 23.4+/-1.2 vs 20.1+/-1.6 cm (P<0.01). Tumors >5 cm in the lower lung region showed a significantly lower mobility compared with tumors <3 cm (1.8+/-1.0 vs 3.8+/-0.7 cm, P<0.01) in the CC directions.

Conclusions: Dynamic MRI is a simple non-invasive method to differentiate mobility of tumors with different diameters and its influence on the surrounding tissue. Tumor diameter has a significant influence on tumor mobility and this might be taken into account in future radiotherapy planning.

Citing Articles

Single institution experience of MRI-guided radiotherapy for thoracic tumors and clinical characteristics impacting treatment duty cycle.

Miccio J, Potter N, Showkat A, Yao M, Mahase S, Ferenci M Front Oncol. 2024; 14:1401703.

PMID: 38919525 PMC: 11196615. DOI: 10.3389/fonc.2024.1401703.


Impact of respiratory motion on lung dose during total marrow irradiation.

Kavak A, Surucu M, Ahn K, Pearson E, Aydogan B Front Oncol. 2022; 12:924961.

PMID: 36330489 PMC: 9622752. DOI: 10.3389/fonc.2022.924961.


Erring Characteristics of Deformable Image Registration-Based Auto-Propagation for Internal Target Volume in Radiotherapy of Locally Advanced Non-Small Cell Lung Cancer.

Rich B, Spieler B, Yang Y, Young L, Amestoy W, Monterroso M Front Oncol. 2022; 12:929727.

PMID: 35936742 PMC: 9353179. DOI: 10.3389/fonc.2022.929727.


Non-rigid image registration of 4D-MRI data for improved delineation of moving tumors.

Weick S, Breuer K, Richter A, Exner F, Strohle S, Lutyj P BMC Med Imaging. 2020; 20(1):41.

PMID: 32326879 PMC: 7178986. DOI: 10.1186/s12880-020-00439-6.


Initial clinical observations of intra- and interfractional motion variation in MR-guided lung SBRT.

Thomas D, Santhanam A, Kishan A, Cao M, Lamb J, Min Y Br J Radiol. 2017; 91(1083):20170522.

PMID: 29166129 PMC: 5965474. DOI: 10.1259/bjr.20170522.