» Articles » PMID: 14716545

Burst Strength of Laparoscopic and Open Hernia Repair

Overview
Journal Surg Endosc
Publisher Springer
Date 2004 Jan 13
PMID 14716545
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Background: There are few reports of overall strength of laparoscopic and open incisional hernia repair.

Methods: After anesthesia, a 2-inch circular defect was made in the abdominal wall of 28 female swine. Gore-Tex DualMesh Biomaterial (W. L. Gore & Associates, Flagstaff, AZ) was used for all repairs. Sixteen animals underwent open repair and 12 underwent laparoscopic repair. Burst strength was detected within 2 weeks and at 6 weeks by euthanizing the animals and insufflating the abdominal cavity with water while measuring the intraabdominal pressure until it could no longer be pressurized.

Results: Three events occurred after insufflation: rupture around patch (R), dissection from insufflation or pressure monitoring sites (D), or rectal prolapse (P). Failure after open early repair occurred at 289 (range 219-388) mmHg with 7-R, 1-P and late 289 (196-343) mmHg with 1-R, 6-P. Failure after laparoscopic early repair occurred at 259 (191-388) mmHg with 4-R, 1-P, 1-D and late 291 (140-330) mmHg with 2-R, 1-P, 3-D. Late groups were less likely to rupture.

Conclusion: Both hernia repairs are durable at early and late periods. Tissue ingrowth adds to repair strength. We could not show that one repair was stronger than the other. Nonetheless, laparoscopic repair tended to degrade by dissection, which was our highest pressure event.

Citing Articles

Comparison of short- to mid-term efficacy of nonfixation and permanent tack fixation in laparoscopic total extraperitoneal hernia repair: A systematic review and meta-analysis.

Lo C, Tsai Y, Yang S, Hsieh C, Chang S Tzu Chi Med J. 2019; 31(4):244-253.

PMID: 31867253 PMC: 6905242. DOI: 10.4103/tcmj.tcmj_47_18.


Mesh repair of common abdominal hernias: a review on experimental and clinical studies.

Penttinen R, Gronroos J Hernia. 2008; 12(4):337-44.

PMID: 18351432 DOI: 10.1007/s10029-008-0362-4.


Biomechanical analyses of mesh fixation in TAPP and TEP hernia repair.

Schwab R, Schumacher O, Junge K, Binnebosel M, Klinge U, Becker H Surg Endosc. 2007; 22(3):731-8.

PMID: 17623239 DOI: 10.1007/s00464-007-9476-5.


Fibrin sealant for mesh fixation in Lichtenstein repair: biomechanical analysis of different techniques.

Schwab R, Schumacher O, Junge K, Binnebosel M, Klinge U, Schumpelick V Hernia. 2007; 11(2):139-45.

PMID: 17252181 DOI: 10.1007/s10029-007-0195-6.

References
1.
Losanoff J, Richman B, Jones J . Entero-colocutaneous fistula: a late consequence of polypropylene mesh abdominal wall repair: case report and review of the literature. Hernia. 2002; 6(3):144-7. DOI: 10.1007/s10029-002-0067-z. View

2.
Cresswell A, Grundstrom H, Thorstensson A . Observations on intra-abdominal pressure and patterns of abdominal intra-muscular activity in man. Acta Physiol Scand. 1992; 144(4):409-18. DOI: 10.1111/j.1748-1716.1992.tb09314.x. View

3.
Bageacu S, Blanc P, Breton C, Gonzales M, Porcheron J, Chabert M . Laparoscopic repair of incisional hernia: a retrospective study of 159 patients. Surg Endosc. 2002; 16(2):345-8. DOI: 10.1007/s00464-001-0018-2. View

4.
Fernandez Lobato R, Martinez Santos C, Ortega Deballon P, Fradejas Lopez J, Marin Lucas F, Moreno Azcoita M . Colocutaneous fistula due to polypropylene mesh. Hernia. 2001; 5(2):107-9. DOI: 10.1007/s100290100003. View

5.
Heniford B, Park A, Ramshaw B, Voeller G . Laparoscopic ventral and incisional hernia repair in 407 patients. J Am Coll Surg. 2000; 190(6):645-50. DOI: 10.1016/s1072-7515(00)00280-5. View