» Articles » PMID: 17623239

Biomechanical Analyses of Mesh Fixation in TAPP and TEP Hernia Repair

Overview
Journal Surg Endosc
Publisher Springer
Date 2007 Jul 12
PMID 17623239
Citations 36
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Reliable laparoscopic fixation of meshes prior to their fibrous incorporation is intended to minimize recurrences following transabdominal preperitoneal hernia repair (TAPP) and totally extraperitoneal repair (TEP) repair of inguinal hernias. However, suture-, tack- and staple-based fixation systems are associated with postoperative chronic inguinal pain. Initial fixation with fibrin sealant offers an atraumatic alternative, but there is little data demonstrating directly whether fibrin-based mesh adhesion provides adequate biomechanical stability for repair of inguinal hernia by TAPP and TEP.

Methods: Using a newly developed, standardized simulation model for abdominal wall hernias, sublay repairs were performed with six different types of commercially available hernia mesh. The biomechanical stability achieved, and the protection afforded by the mesh-hernia overlap, were compared for three different techniques: nonfixation, point-by-point suture fixation, and fibrin sealant fixation.

Results: Mesh dislocation from the repaired hernia defect was consistently seen with nonfixation. This was reliably prevented with all six mesh types when fixed using either sutures or fibrin sealant. The highest stress resistance across the whole abdominal wall was found following superficial fixation with fibrin sealant across the mesh types. There was a highly statistically significant improvement in fixation stability with fibrin sealant versus fixation using eight single sutures (p = 0.008), as assessed by the range of achievable peak pressure stress up to 200 mmHg.

Conclusions: To ensure long-term freedom from recurrence, intraoperative mesh-hernia overlap must be retained. This can be achieved with fibrin sealant up to the incorporation of the mesh - without trauma and with biomechanical stability.

Citing Articles

Prospective randomized study comparing mesh displacement in enhanced-view totally extraperitoneal versus totally extraperitoneal laparoscopic inguinal hernia repair without mesh fixation.

Yilmaz A, Ulutas M, Turkoglu S Hernia. 2024; 28(6):2393-2401.

PMID: 39325327 DOI: 10.1007/s10029-024-03181-y.


Study of the biomechanical response of a prosthetic mesh secured with penetrating and non-penetrating fixations in IPOM ventral hernia repair.

Vegleur A, Le Ruyet A Hernia. 2023; 28(1):75-84.

PMID: 37964087 DOI: 10.1007/s10029-023-02915-8.


Is mesh fixation necessary in laparoendoscopic techniques for M3 inguinal defects? An experimental study.

Zamkowski M, Tomaszewska A, Lubowiecka I, Karbowski K, Smietanski M Surg Endosc. 2022; 37(3):1781-1788.

PMID: 36229552 DOI: 10.1007/s00464-022-09699-5.


Fascinating history of groin hernias: Comprehensive recognition of anatomy, classic considerations for herniorrhaphy, and current controversies in hernioplasty.

Hori T, Yasukawa D World J Methodol. 2021; 11(4):160-186.

PMID: 34322367 PMC: 8299909. DOI: 10.5662/wjm.v11.i4.160.


Crucial anatomy and technical cues for laparoscopic transabdominal preperitoneal repair: Advanced manipulation for groin hernias in adults.

Yasukawa D, Aisu Y, Hori T World J Gastrointest Surg. 2020; 12(7):307-325.

PMID: 32821340 PMC: 7407845. DOI: 10.4240/wjgs.v12.i7.307.


References
1.
Kumar S, Wilson R, Nixon S, Macintyre I . Chronic pain after laparoscopic and open mesh repair of groin hernia. Br J Surg. 2002; 89(11):1476-9. DOI: 10.1046/j.1365-2168.2002.02260.x. View

2.
Zieren J, CASTENHOLZ E, Jacobi C, Zieren H, Muller J . Is mesh fixation necessary in abdominal hernia repair? Results of an experimental study in the rat. Langenbecks Arch Surg. 1999; 384(1):71-5. DOI: 10.1007/s004230050177. View

3.
Neumayer L, Giobbie-Hurder A, Jonasson O, Fitzgibbons Jr R, Dunlop D, Gibbs J . Open mesh versus laparoscopic mesh repair of inguinal hernia. N Engl J Med. 2004; 350(18):1819-27. DOI: 10.1056/NEJMoa040093. View

4.
Petter-Puchner A, Fortelny R, Mittermayr R, Ohlinger W, Redl H . Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat. Hernia. 2005; 9(4):322-9. DOI: 10.1007/s10029-005-0009-7. View

5.
Callesen T, Bech K, Kehlet H . Prospective study of chronic pain after groin hernia repair. Br J Surg. 1999; 86(12):1528-31. DOI: 10.1046/j.1365-2168.1999.01320.x. View