» Articles » PMID: 14599568

The Spatiotemporal Precision of Ganglion Cell Signals: a Comparison of Physiological and Psychophysical Performance with Moving Gratings

Overview
Journal Vision Res
Specialty Ophthalmology
Date 2003 Nov 6
PMID 14599568
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Comparison of the spatiotemporal information delivered by ganglion cells with human psychophysical performance may give insight to how retinal information is utilized by cortical mechanisms, and constrain models of spatiotemporal processing. Ganglion cells' responses were measured with drifting gratings of various spatial and temporal frequencies and contrasts. The spatiotemporal precision of cell responses was estimated in terms of a noise measure and phase variation, and compared to human vernier performance. Noise and phase variation of magnocellular (MC) cells was least at low temporal frequencies, despite their transient responses. The patterns of spatiotemporal precision of MC cells resembled the patterns of human vernier thresholds while those of parvocellular cells did not, implying use of MC cells' signals in these tasks. The analysis further implied that cortical mechanisms must perform a sophisticated spatiotemporal analysis over local ganglion cell arrays.

Citing Articles

Signaling - transcription interactions in mouse retinal ganglion cells early axon pathfinding -a literature review.

Pascalau R, Badea T Front Ophthalmol (Lausanne). 2024; 3:1180142.

PMID: 38983012 PMC: 11182120. DOI: 10.3389/fopht.2023.1180142.


Detection and discrimination of achromatic contrast: A ganglion cell perspective.

Lee B, Swanson W J Vis. 2022; 22(8):11.

PMID: 35848903 PMC: 9308016. DOI: 10.1167/jov.22.8.11.


Bioplausible multiscale filtering in retino-cortical processing as a mechanism in perceptual grouping.

Nematzadeh N, Powers D, Lewis T Brain Inform. 2017; 4(4):271-293.

PMID: 28887785 PMC: 5709283. DOI: 10.1007/s40708-017-0072-8.


Macaque retinal ganglion cell responses to visual patterns: harmonic composition, noise, and psychophysical detectability.

Cooper B, Lee B, Cao D J Neurophysiol. 2016; 115(6):2976-88.

PMID: 26936977 PMC: 4922617. DOI: 10.1152/jn.00411.2015.


A method for electrophysiological characterization of hamster retinal ganglion cells using a high-density CMOS microelectrode array.

Jones I, Russell T, Farrow K, Fiscella M, Franke F, Muller J Front Neurosci. 2015; 9:360.

PMID: 26528115 PMC: 4602149. DOI: 10.3389/fnins.2015.00360.