» Articles » PMID: 12598555

Persistent Acute Inflammation at the Implant-abutment Interface

Overview
Journal J Dent Res
Specialty Dentistry
Date 2003 Feb 25
PMID 12598555
Citations 64
Authors
Affiliations
Soon will be listed here.
Abstract

The inflammatory response adjacent to implants has not been well-investigated and may influence peri-implant tissue levels. The purpose of this study was to assess, histomorphometrically, (1) the timing of abutment connection and (2) the influence of a microgap. Three implant designs were placed in the mandibles of dogs. Two-piece implants were placed at the alveolar crest and abutments connected either at initial surgery (non-submerged) or three months later (submerged). The third implant was one-piece. Adjacent interstitial tissues were analyzed. Both two-piece implants resulted in a peak of inflammatory cells approximately 0.50 mm coronal to the microgap and consisted primarily of neutrophilic polymorphonuclear leukocytes. For one-piece implants, no such peak was observed. Also, significantly greater bone loss was observed for both two-piece implants compared with one-piece implants. In summary, the absence of an implant-abutment interface (microgap) at the bone crest was associated with reduced peri-implant inflammatory cell accumulation and minimal bone loss.

Citing Articles

The impact of a 1 mm interimplant distance on the interproximal crestal bone height: a case report with a 10-year follow-up and literature review.

Morales Schwarz D, Szmukler-Moncler S, Morales Melendez H, Beuer F Int J Implant Dent. 2025; 11(1):8.

PMID: 39890702 PMC: 11785880. DOI: 10.1186/s40729-025-00589-8.


Evaluation of the influence of connection configuration on the implant-abutment interface vertical misfit of original milled titanium and laser-sintered cobalt-chromium abutments.

Diaz P, Vizoso B, Lopez-Suarez C, Gonzalo E, Mosaddad S, Suarez M Clin Oral Investig. 2025; 29(1):72.

PMID: 39841269 DOI: 10.1007/s00784-024-06093-4.


A New Multi-Axial Functional Stress Analysis Assessing the Longevity of a Ti-6Al-4V Dental Implant Abutment Screw.

Naguib G, Abougazia A, Al-Turki L, Mously H, Hashem A, Mira A Biomimetics (Basel). 2024; 9(11).

PMID: 39590261 PMC: 11591605. DOI: 10.3390/biomimetics9110689.


Multiaxial fatigue life assessment of dental implants.

Armentia M, Abasolo M, Coria I, Saintier N Heliyon. 2024; 10(19):e36777.

PMID: 39386765 PMC: 11462250. DOI: 10.1016/j.heliyon.2024.e36777.


Engaging vs. Non-Engaging Abutments: An In Vitro Study Evaluating Changes in Microgap and Screw Morphology.

Alzoubi F, Sabti M, Alsarraf E, Alshahrani F, Sadowsky S Dent J (Basel). 2024; 12(8).

PMID: 39195109 PMC: 11354066. DOI: 10.3390/dj12080265.