Abstract

This study investigates the impact of tightening torque (preload) and the friction coefficient on stress generation and fatigue resistance of a Ti-6Al-4V abutment screw with an internal hexagonal connection under dynamic multi-axial masticatory loads in high-cycle fatigue (HCF) conditions. A three-dimensional model of the implant-abutment assembly was simulated using ANSYS Workbench 16.2 computer aided engineering software with chewing forces ranging from 300 N to 1000 N, evaluated over 1.35 × 10 cycles, simulating 15 years of service. Results indicate that the healthy range of normal to maximal mastication forces (300-550 N) preserved the screw's structural integrity, while higher loads (≥800 N) exceeded the Ti-6Al-4V alloy's yield strength, indicating a risk of plastic deformation under extreme conditions. Stress peaked near the end of the occluding phase (206.5 ms), marking a critical temporal point for fatigue accumulation. Optimizing the friction coefficient (0.5 µ) and preload management improved stress distribution, minimized fatigue damage, and ensured joint stability. Masticatory forces up to 550 N were well within the abutment screw's capacity to sustain extended service life and maintain its elastic behavior.

References
1.
Tzenakis G, Nagy W, Fournelle R, Dhuru V . The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws. J Prosthet Dent. 2002; 88(2):183-91. DOI: 10.1067/mpr.2002.127604. View

2.
Wentaschek S, Tomalla S, Schmidtmann I, Lehmann K . Preload, Coefficient of Friction, and Thread Friction in an Implant-Abutment-Screw Complex. Int J Prosthodont. 2017; 30(6):542-544. DOI: 10.11607/ijp.5286. View

3.
Jafari B, Katoozian H, Tahani M, Ashjaee N . A comparative study of bone remodeling around hydroxyapatite-coated and novel radial functionally graded dental implants using finite element simulation. Med Eng Phys. 2022; 102:103775. DOI: 10.1016/j.medengphy.2022.103775. View

4.
Marghalani T, Hamed M, Awad M, Naguib G, Elragi A . Three-dimensional finite element analysis of custom-made ceramic dowel made using CAD/CAM technology. J Prosthodont. 2012; 21(6):440-50. DOI: 10.1111/j.1532-849X.2012.00860.x. View

5.
Lang L, Kang B, Wang R, Lang B . Finite element analysis to determine implant preload. J Prosthet Dent. 2003; 90(6):539-46. DOI: 10.1016/j.prosdent.2003.09.012. View