» Articles » PMID: 11938503

Independent Contribution of Elevated-rim Acetabular Liner and Femoral Head Size to the Stability of Total Hip Implants

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2002 Apr 9
PMID 11938503
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

The use of an elevated-rim acetabular liner in total hip arthroplasty is widely accepted. We sought to determine quantitatively the amount of additional stability provided by the elevated-rim liner compared with the standard nonelevated liner. The stability of the hip with a 32-mm femoral head was compared with the standard 28-mm head. Our results show that a 15 degrees elevated-rim acetabular liner placed in the posterior quadrant increased hip stability by an additional 8.9 degrees of internal rotation. Similarly the 32-mm head provided 8.1 degrees of additional internal rotation. The increases were statistically significant (P<.0001). We did not encounter increased anterior dislocation intraoperatively. The findings of this study indicate that the 32-mm head may contribute to hip stability in primary total hip arthroplasty, and in instances in which a posterior approach is used, an elevated-rim liner placed in the posterior quadrant may contribute independently to hip stability.

Citing Articles

Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients.

Cha Y, Lee S, Bae J, Kang Y, Baek J, Kang J Clin Orthop Surg. 2025; 17(1):62-70.

PMID: 39912063 PMC: 11791493. DOI: 10.4055/cios24148.


Defining the optimal position of the lipped liner in combination with cup orientation and stem version.

Navacchia A, Pagkalos J, Davis E Bone Joint Res. 2023; 12(9):571-579.

PMID: 37727965 PMC: 10509720. DOI: 10.1302/2046-3758.129.BJR-2022-0471.R1.


Computer simulation of optimal lipped polyethylene liner orientation against prosthetic impingement.

Hu Y, Zhou X, Qiao H, Zhu Z, Li H, Zhang J J Orthop Surg Res. 2022; 17(1):204.

PMID: 35379266 PMC: 8981617. DOI: 10.1186/s13018-022-03093-6.


Impingement in total hip arthroplasty: A geometric model.

Pryce G, Sabu B, Al-Hajjar M, Wilcox R, Thompson J, Isaac G Proc Inst Mech Eng H. 2022; :9544119211069472.

PMID: 35147063 PMC: 8915222. DOI: 10.1177/09544119211069472.


Using an asymmetric crosslinked polyethylene liner in primary total hip arthroplasty is associated with a lower risk of revision surgery : an analysis of the National Joint Registry.

Davis E, Pagkalos J, Kopjar B Bone Joint J. 2021; 103-B(9):1479-1487.

PMID: 34465151 PMC: 9948452. DOI: 10.1302/0301-620X.103B9.BJJ-2021-0365.R1.