» Articles » PMID: 11477648

Measuring the Human Retinal Oxygenation Response to a Hyperoxic Challenge Using MRI: Eliminating Blinking Artifacts and Demonstrating Proof of Concept

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2001 Jul 31
PMID 11477648
Citations 41
Authors
Affiliations
Soon will be listed here.
Abstract

The retinal oxygenation response to a hyperoxic challenge measured using MRI appears to be an early and accurate marker of retinopathy risk in experimental models, with promising clinical potential. However, the application of this technique in humans is limited by blinking artifacts that can confound detection of subtle signal intensity changes. We asked subjects to refrain from blinking during a 12-s fast low-angle shot (FLASH) image, and to blink if needed during the following 3-s rest period. This no-blink blink cycle was repeated sequentially 20 times during either room-air or 100% oxygen breathing. Significant change (P < 0.05) was detected for the first time from the resultant blinking-artifact-free images in the preretinal vitreous oxygen tension (upper limit of about 13 mm Hg (1.8 KPa, N = 3)) following a 10-min hyperoxic inhalation challenge. These results provide the proof-of-concept data needed for future MRI evaluation of the retinal oxygenation response and human retinopathy, such as diabetic retinopathy.

Citing Articles

Geometrical accuracy of magnetic resonance imaging for ocular proton therapy planning.

Klaassen L, Haasjes C, Hol M, Cambraia Lopes P, Spruijt K, Van De Steeg-Henzen C Phys Imaging Radiat Oncol. 2024; 31:100598.

PMID: 38993288 PMC: 11234150. DOI: 10.1016/j.phro.2024.100598.


Eye Size and Shape in Relation to Refractive Error in Children: A Magnetic Resonance Imaging Study.

Kneepkens S, Marstal K, Polling J, Jaddoe V, Vernooij M, Poot D Invest Ophthalmol Vis Sci. 2023; 64(15):41.

PMID: 38153751 PMC: 10756250. DOI: 10.1167/iovs.64.15.41.


Magnetic Resonance Imaging in the Clinical Care for Uveal Melanoma Patients-A Systematic Review from an Ophthalmic Perspective.

Jaarsma-Coes M, Klaassen L, Marinkovic M, Luyten G, Vu T, Ferreira T Cancers (Basel). 2023; 15(11).

PMID: 37296958 PMC: 10252038. DOI: 10.3390/cancers15112995.


Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma.

Jaarsma-Coes M, Klaassen L, Verbist B, Vu T, Klaver Y, Rodrigues M Adv Radiat Oncol. 2023; 8(3):101149.

PMID: 36691449 PMC: 9860418. DOI: 10.1016/j.adro.2022.101149.


Chorioretinal Hypoxia Detection Using Lipid-Polymer Hybrid Organic Room-Temperature Phosphorescent Nanoparticles.

Zeng Y, Nguyen V, Li Y, Kang D, Paulus Y, Kim J ACS Appl Mater Interfaces. 2022; 14(16):18182-18193.

PMID: 35420786 PMC: 9780709. DOI: 10.1021/acsami.2c02767.