» Articles » PMID: 11311703

"In Vivo" Determination of Hip Joint Separation and the Forces Generated Due to Impact Loading Conditions

Overview
Journal J Biomech
Specialty Physiology
Date 2001 Apr 20
PMID 11311703
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Numerous supporting structures assist in the retention of the femoral head within the acetabulum of the normal hip joint including the capsule, labrum, and ligament of the femoral head (LHF). During total hip arthroplasty (THA), the LHF is often disrupted or degenerative and is surgically removed. In addition, a portion of the remaining supporting structures is transected or resected to facilitate surgical exposure. The present study analyzes the effects of LHF absence and surgical dissection in THA patients. Twenty subjects (5 normal hip joints, 10 nonconstrained THA, and 5 constrained THA) were evaluated using fluoroscopy while performing active hip abduction. All THA subjects were considered clinically successful. Fluoroscopic videos of the normal hips were analyzed using digitization, while those with THA were assessed using a computerized interactive model-fitting technique. The distance between the femoral head and acetabulum was measured to determine if femoral head separation occurred. Error analysis revealed measurements to be accurate within 0.75mm. No separation was observed in normal hips or those subjects implanted with constrained THA, while all 10 (100%) with unconstrained THA demonstrated femoral head separation, averaging 3.3mm (range 1.9-5.2mm). This study has shown that separation of the prosthetic femoral head from the acetabular component can occur. The normal hip joint has surrounding capsuloligamentous structures and a ligament attaching the femoral head to the acetabulum. We hypothesize that these soft tissue supports create a passive, resistant force at the hip, preventing femoral head separation. The absence of these supporting structures after THA may allow increased hip joint forces, which may play a role in premature polyethylene wear or prosthetic loosening.

Citing Articles

Do component position and muscle strength affect the cup-head translation during gait after total hip arthroplasty?.

Kiyohara M, Hamai S, Hara D, Fujiyoshi D, Harada S, Kawaguchi K Eur J Orthop Surg Traumatol. 2019; 29(6):1263-1269.

PMID: 31037407 DOI: 10.1007/s00590-019-02443-1.


An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements.

ODwyer Lancaster-Jones O, Williams S, Jennings L, Thompson J, Isaac G, Fisher J J Biomed Mater Res B Appl Biomater. 2017; 106(5):1897-1906.

PMID: 28941162 PMC: 6088455. DOI: 10.1002/jbm.b.33991.


Effect of an edge at cup rim on contact stress during micro-separation in ceramic-on-ceramic hip joints.

Liu F, Fisher J Tribol Int. 2017; 113:323-329.

PMID: 28867870 PMC: 5465945. DOI: 10.1016/j.triboint.2017.01.012.


Ageing, Shocks and Wear Mechanisms in ZTA and the Long-Term Performance of Hip Joint Materials.

Perrichon A, Liu B, Chevalier J, Gremillard L, Reynard B, Farizon F Materials (Basel). 2017; 10(6).

PMID: 28772930 PMC: 5541297. DOI: 10.3390/ma10060569.


Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty.

Wu G, Zhu W, Zhao Y, Ma Q, Weng X Chin Med J (Engl). 2016; 129(15):1861-6.

PMID: 27453238 PMC: 4976577. DOI: 10.4103/0366-6999.186654.