» Authors » Vojko Jazbinsek

Vojko Jazbinsek

Explore the profile of Vojko Jazbinsek including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 11
Citations 84
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Marhl U, Sander T, Jazbinsek V
Sensors (Basel) . 2022 May; 22(9). PMID: 35590874
Magnetoencephalography (MEG) is a neuroimaging technique that measures the magnetic fields of the brain outside of the head. In the past, the most suitable magnetometer for MEG was the superconducting...
2.
Marhl U, Jodko-Wladzinska A, Bruhl R, Sander T, Jazbinsek V
PLoS One . 2022 Jan; 17(1):e0262669. PMID: 35045107
Optically pumped magnetometers (OPMs) have recently become so sensitive that they are suitable for use in magnetoencephalography (MEG). These sensors solve operational problems of the current standard MEG, where superconducting...
3.
Trontelj Z, Luznik J, Pirnat J, Jazbinsek V, Lavric Z, Srcic S
J Pharm Sci . 2019 May; 108(9):2865-2870. PMID: 31128123
To demonstrate the selectivity of N nuclear quadrupole resonance (N NQR) spectroscopy in chemistry and pharmacy, a study of sulfanilamide polymorphism was undertaken. We studied 3 known polymorphs of sulfanilamide...
4.
Begus S, Jazbinsek V, Pirnat J, Trontelj Z
J Magn Reson . 2014 Sep; 247:22-30. PMID: 25233110
A low frequency (0.5-5 MHz) battery operated sensitive pulsed NQR spectrometer with a transmitter power up to 5 W and a total mass of about 3 kg aimed at detecting...
5.
Luznik J, Pirnat J, Jazbinsek V, Lavric Z, Zagar V, Srcic S, et al.
J Pharm Sci . 2014 Mar; 103(9):2704-2709. PMID: 24668530
(14)N nuclear quadrupole resonance (NQR) in two known polymorphs of famotidine was measured. At room temperature, seven quadrupolar sets of transition frequencies (ν(+), ν(-), and ν(0)) corresponding to seven different...
6.
Milanic M, Jazbinsek V, MacLeod R, Brooks D, Hren R
J Electrocardiol . 2013 Dec; 47(1):20-8. PMID: 24369741
A widely used approach to solving the inverse problem in electrocardiography involves computing potentials on the epicardium from measured electrocardiograms (ECGs) on the torso surface. The main challenge of solving...
7.
Korber R, Nieminen J, Hofner N, Jazbinsek V, Scheer H, Kim K, et al.
J Magn Reson . 2013 Nov; 237:182-190. PMID: 24252245
In ultra-low-field (ULF) NMR/MRI, a common scheme is to magnetize the sample by a polarizing field of up to hundreds of mT, after which the NMR signal, precessing in a...
8.
Kim K, Begus S, Xia H, Lee S, Jazbinsek V, Trontelj Z, et al.
Neuroimage . 2013 Nov; 89:143-51. PMID: 24185014
Atomic magnetometers are emerging as an alternative to SQUID magnetometers for detection of biological magnetic fields. They have been used to measure both the magnetocardiography (MCG) and magnetoencephalography (MEG) signals....
9.
Lahajnar G, Sobotic B, Sepe A, Jazbinsek V, Pecar S
Gen Physiol Biophys . 2010 Dec; 29(4):373-80. PMID: 21157000
Sodium nitroprusside (SNP) is a nitric oxide (•NO) donor in vitro and in vivo. In this paper the time variation of the intracellular water proton nuclear magnetic resonance (NMR) effective...
10.
Jazbinsek V, Luznik J, Mieke S, Trontelj Z
Ann Biomed Eng . 2009 Dec; 38(3):774-87. PMID: 19953320
Most non-invasive blood pressure measurements are based on either the auscultatory or the oscillometric technique. In this study, we performed an extensive analysis of the signals, i.e., responses of a...