Tahmina Achekzai
Overview
Explore the profile of Tahmina Achekzai including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
7
Citations
35
Followers
0
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Achekzai T, Ruppert K, Loza L, Amzajerdian F, Profka H, Duncan I, et al.
Magn Reson Med
. 2022 Sep;
88(6):2447-2460.
PMID: 36046917
Purpose: To demonstrate the utility of continuous-wave (CW) saturation pulses in xenon-polarization transfer contrast (XTC) MRI and MRS, to investigate the selectivity of CW pulses applied to dissolved-phase resonances, and...
2.
Amzajerdian F, Ruppert K, Hamedani H, Baron R, Xin Y, Loza L, et al.
Magn Reson Med
. 2020 Dec;
85(5):2709-2722.
PMID: 33283943
Purpose: To demonstrate the feasibility of generating red blood cell (RBC) and tissue/plasma (TP)-specific gas-phase (GP) depolarization maps using xenon-polarization transfer contrast (XTC) MR imaging. Methods: Imaging was performed in...
3.
Ruppert K, Amzajerdian F, Xin Y, Hamedani H, Loza L, Achekzai T, et al.
Magn Reson Med
. 2020 Jun;
84(6):3027-3039.
PMID: 32557808
Purpose: To investigate biases in the measurement of apparent alveolar septal wall thickness (SWT) with hyperpolarized xenon-129 (HXe) as a function of acquisition parameters. Methods: The HXe MRI scans with...
4.
Ruppert K, Xin Y, Hamedani H, Amzajerdian F, Loza L, Achekzai T, et al.
Sci Rep
. 2019 Feb;
9(1):2413.
PMID: 30787357
While hyperpolarized xenon-129 (HXe) MRI offers a wide array of tools for assessing functional aspects of the lung, existing techniques provide only limited quantitative information about the impact of an...
5.
Achekzai T, Hamedani H, Kadlecek S, Ruppert K, Xin Y, Baron R, et al.
Acad Radiol
. 2019 Jan;
26(3):367-382.
PMID: 30630659
Rationale And Objectives: In this study, we compared a newly developed multibreath simultaneous alveolar oxygen tension and apparent diffusion coefficient (PO-ADC) imaging sequence to a single-breath acquisition, with the aim...
6.
Ruppert K, Amzajerdian F, Hamedani H, Xin Y, Loza L, Achekzai T, et al.
Magn Reson Med
. 2018 Oct;
81(3):1784-1794.
PMID: 30346083
Purpose: To investigate the feasibility of describing the impact of any flip angle-TR combination on the resulting distribution of the hyperpolarized xenon-129 (HXe) dissolved-phase magnetization in the chest using a...
7.
Ruppert K, Amzajerdian F, Hamedani H, Xin Y, Loza L, Achekzai T, et al.
Magn Reson Med
. 2018 Apr;
80(6):2439-2448.
PMID: 29682792
Purpose: To demonstrate the feasibility of using a 3D radial double golden-means acquisition with variable flip angles to monitor pulmonary gas transport in a single breath hold with hyperpolarized xenon-129...