Lance J Wilson
Overview
Explore the profile of Lance J Wilson including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
9
Citations
42
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Reynolds M, MacGregor D, Barry M, Lottering N, Schmutz B, Wilson L, et al.
Forensic Sci Int
. 2017 Aug;
278:381-387.
PMID: 28810162
This study introduces a standardized protocol for conducting linear measurements of postcranial skeletal elements using three-dimensional (3D) models constructed from post-mortem computed tomography (PMCT) scans. Using femoral DICOM datasets, reference...
2.
Can larger-bodied cemented femoral components reduce periprosthetic fractures? A biomechanical study
Ginsel B, Morishima T, Wilson L, Whitehouse S, Crawford R
Arch Orthop Trauma Surg
. 2015 Mar;
135(4):517-22.
PMID: 25724411
Introduction: The risk for late periprosthetic femoral fractures is higher in patients treated for a neck of femur fracture compared to osteoarthritis. It has been hypothesised that osteopaenia and consequent...
3.
Morishima T, Choy G, Crawford R, Wilson L
J Orthop Surg (Hong Kong)
. 2014 Aug;
22(2):163-7.
PMID: 25163947
Purpose: To compare pressures generated by 2 different cement pressurisers at various locations in the proximal femur. Methods: Two groups of 5 synthetic femurs were used, and 6 pressure sensors...
4.
Grant C, Wilson L, Langton C, Epari D
Med Eng Phys
. 2014 May;
36(7):869-74.
PMID: 24793408
Finite element models of bones can be created by deriving geometry from an X-ray CT scan. Material properties such as the elastic modulus can then be applied using either a...
5.
Morishima T, Ginsel B, Choy G, Wilson L, Whitehouse S, Crawford R
J Arthroplasty
. 2013 Dec;
29(5):1067-71.
PMID: 24295802
In an attempt to preserve proximal femoral bone stock and achieve a better fit in smaller femora, especially in the Asian population, several new shorter stem designs have become available....
6.
Crawford R, Whitehouse S, Brew C, Wilson L, Hubble M
J Arthroplasty
. 2013 Jun;
28(8):1446-7.
PMID: 23806184
No abstract available.
7.
Brew C, Wilson L, Whitehouse S, Hubble M, Crawford R
J Arthroplasty
. 2012 Nov;
28(3):521-5.
PMID: 23146585
The aim of this study was to perform a biomechanical analysis of the cement-in-cement (c-in-c) technique for fixation of selected Vancouver Type B1 femoral periprosthetic fractures and to assess the...
8.
Wilson L, Roe J, Pearcy M, Crawford R
J Arthroplasty
. 2011 Dec;
27(6):934-9.
PMID: 22146384
The Exeter stems vary in length from 90 to 150 mm. The shorter stems generally have lower offsets. The purpose of this study was to determine if length of stem,...
9.
Wilson L, Richards C, Irvine D, Tillie A, Crawford R
Acta Orthop
. 2011 Nov;
82(6):674-8.
PMID: 22066561
Background And Purpose: Removal of distal cement at femoral implant revision is technically challenging and is associated with complications such as cortical perforations. A technique that can reduce the risks...