» Authors » Gordon A Thomas

Gordon A Thomas

Explore the profile of Gordon A Thomas including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 8
Citations 26
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Lakshmanan S, Kanwal A, Liu S, Patlolla A, Iqbal Z, Mitra S, et al.
Micromachines (Basel) . 2020 Apr; 11(3). PMID: 32245014
Under certain conditions, electrophoretic deposition (EPD) of single-wall carbon nanotubes (SWCNTs) onto metal at the base of nanoscale insulating windows can result in a single SWCNT per window, bonded at...
2.
Apigo D, Kanwal A, Palmieri J, Dobiszewski K, Farrow R, Thomas G, et al.
Sci Rep . 2018 Feb; 8(1):3324. PMID: 29463800
Large classes of electronic, photonic, and acoustic crystals and quasi-crystals have been predicted to support topological wave-modes. Some of these modes are stabilized by certain symmetries but others occur as...
3.
Apigo D, Bartholomew P, Russell T, Kanwal A, Farrow R, Thomas G
Sens Actuators A Phys . 2017 May; 251:234-240. PMID: 28533631
A device, with MEMS sensors at its core, has been fabricated and tested for measuring low fluid pressure and slow flow rates. The motivation was to measure clinically relevant ranges...
4.
Apigo D, Bartholomew P, Russell T, Kanwal A, Farrow R, Thomas G
Sci Rep . 2017 Apr; 7:46039. PMID: 28378775
A sensor was tested subdural and in vitro, simulating a supine infant with a ventricular-peritoneal shunt and controlled occlusions. The variable MEMS capacitive device is able to detect and forecast...
5.
Raj R, Lakshmanan S, Apigo D, Kanwal A, Liu S, Russell T, et al.
Sens Actuators A Phys . 2015 Nov; 234:223-231. PMID: 26543321
A flow sensor has been fabricated and tested that is capable of measuring the slow flow characteristic of the cerebrospinal fluid in the range from less than 4 mL/h to...
6.
Kanwal A, Lakshmanan S, Bendiganavale A, Bot C, Patlolla A, Raj R, et al.
Biosens Bioelectron . 2013 Mar; 45:267-73. PMID: 23500374
Here we present a carbon nanotube based device to noninvasively and quickly detect mobile single cells with the potential to maintain a high degree of spatial resolution. The device utilizes...
7.
Alvarez T, Gollance S, Thomas G, Greene R, Marchetto P, Moore E, et al.
Ophthalmology . 2004 Jun; 111(6):1077-85. PMID: 15177956
Purpose: To evaluate the Proview Eye Pressure Monitor as a medical instrument and as a technique for enabling a patient to obtain an accurate measure of his or her intraocular...
8.
Siegrist T, Kloc C, Schon J, Batlogg B, Haddon R, Berg S, et al.
Angew Chem Int Ed Engl . 2001 May; 40(9):1732-1736. PMID: 11353494
No abstract available.