» Authors » D S Baer

D S Baer

Explore the profile of D S Baer including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 15
Citations 26
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Mihalcea R, Baer D, Hanson R
Appl Opt . 2010 Nov; 35(21):4059-64. PMID: 21102811
Two single-mode diode lasers were used to record high-resolution absorption spectra of NO(2) (dilute in Ar) near 670.2 and 394.5 nm over a range of temperatures (296 to 774 K)...
2.
Nagali V, Chou S, Baer D, Hanson R, Segall J
Appl Opt . 2010 Nov; 35(21):4026-32. PMID: 21102806
A diode-laser sensor system based on absorption spectroscopy techniques has been developed to monitor CH(4) nonintrusively in high-temperature environments. Fundamental spectroscopic parameters, including the line strengths of the transitions in...
3.
Baer D, Hanson R
Appl Opt . 2010 Aug; 32(6):948-55. PMID: 20802772
Plasma diagnostics based on saturated fluorescence and absorption spectroscopy with a semiconductor (diode) laser are developed to probe the 4s(3)P(1) ? 4p(3)D(2) transition (8425 A) of argon in an atmospheric...
4.
Baer D, Hanson R, Newfield M, Gopaul N
Opt Lett . 2009 Oct; 19(22):1900. PMID: 19855691
No abstract available.
5.
Arroyo M, Birbeck T, Baer D, Hanson R
Opt Lett . 2009 Oct; 19(14):1091-3. PMID: 19844543
We present a novel diode-laser diagnostic for water-vapor measurements based on absorption spectroscopy. Two InGaAsP diode lasers were used to record H(2)O absorption line shapes near 1395 nm at a...
6.
Webber M, Baer D, Hanson R
Appl Opt . 2008 Mar; 40(12):2031-42. PMID: 18357207
We investigated ammonia spectroscopy near 1.5 mum to select transitions appropriate for trace ammonia detection in air-quality and combustion emissions-monitoring applications using diode lasers. Six ammonia features were selected for...
7.
Webber M, Kim S, Sanders S, Baer D, Hanson R, Ikeda Y
Appl Opt . 2008 Mar; 40(6):821-8. PMID: 18357062
High-resolution absorption measurements of CO(2) were made in a heated static cell and in the combustion region above a flat-flame burner for the development of an in situ CO(2) combustion...
8.
Wang J, Maiorov M, Baer D, Garbuzov D, Connolly J, Hanson R
Appl Opt . 2008 Mar; 39(30):5579-89. PMID: 18354555
In situ measurements of CO concentration were recorded with tunable diode-laser absorption spectroscopy techniques in both the exhaust and the immediate post-flame regions of an atmospheric-pressure flat-flame burner operating on...
9.
Totschnig G, Baer D, Wang J, Winter F, Hofbauer H, Hanson R
Appl Opt . 2008 Mar; 39(12):2009-16. PMID: 18345101
Rapid cavity ringdown measurements of multiple broadband absorbing species (methanol and isopropanol) in gas mixtures have been recorded with two multiplexed continuous-wave distributed-feedback diode lasers operating near 1.4 mum. A...
10.
Mihalcea R, Baer D, Hanson R
Appl Opt . 2008 Feb; 37(36):8341-7. PMID: 18301657
A diode-laser sensor system based on absorption spectroscopy techniques has been developed for nonintrusive measurements of CO(2) in high-temperature environments. Survey spectra of the CO(2) (20 degrees 1,04 degrees 1)(I)-00...