C R Maurer Jr
Overview
Explore the profile of C R Maurer Jr including associated specialties, affiliations and a list of published articles.
Author names and details appear as published. Due to indexing inconsistencies, multiple individuals may share a name, and a single author may have variations. MedLuna displays this data as publicly available, without modification or verification
Snapshot
Snapshot
Articles
27
Citations
1010
Followers
0
Related Specialties
Related Specialties
Top 10 Co-Authors
Top 10 Co-Authors
Published In
Published In
Affiliations
Affiliations
Soon will be listed here.
Recent Articles
1.
Kilby W, Dooley J, Kuduvalli G, Sayeh S, Maurer Jr C
Technol Cancer Res Treat
. 2010 Sep;
9(5):433-52.
PMID: 20815415
This review provides a complete technical description of the CyberKnife VSI System, the latest addition to the CyberKnife product family, which was released in September 2009. This review updates the...
2.
Echner G, Kilby W, Lee M, Earnst E, Sayeh S, Schlaefer A, et al.
Phys Med Biol
. 2009 Aug;
54(18):5359-80.
PMID: 19687567
Robotic radiosurgery using more than one circular collimator can improve treatment plan quality and reduce total monitor units (MU). The rationale for an iris collimator that allows the field size...
3.
Rohlfing T, Maurer Jr C
Med Image Comput Comput Assist Interv
. 2006 May;
8(Pt 2):838-45.
PMID: 16686038
Combination of multiple segmentations has recently been introduced as an effective method to obtain segmentations that are more accurate than any of the individual input segmentations. This paper introduces a...
4.
Hummel J, Figl M, Birkfellner W, Bax M, Shahidi R, Maurer Jr C, et al.
Phys Med Biol
. 2006 May;
51(10):N205-10.
PMID: 16675856
This note uses a published protocol to evaluate a newly released 6 degrees of freedom electromagnetic tracking system (Aurora, Northern Digital Inc.). A practice for performance monitoring over time is...
5.
Hartkens T, Hill D, Castellano-Smith A, Hawkes D, Maurer Jr C, Martin A, et al.
IEEE Trans Med Imaging
. 2003 Apr;
22(1):82-92.
PMID: 12703762
Recent studies have shown that the surface of the brain is deformed by up to 20 mm after the skull is opened during neurosurgery, which could lead to substantial error...
6.
Mori K, Deguchi D, Sugiyama J, Suenaga Y, Toriwaki J, Maurer Jr C, et al.
Med Image Anal
. 2002 Sep;
6(3):321-36.
PMID: 12270236
This paper describes a method for tracking the camera motion of a flexible endoscope, in particular a bronchoscope, using epipolar geometry analysis and intensity-based image registration. The method proposed here...
7.
West J, Fitzpatrick J, Toms S, Maurer Jr C, Maciunas R
Neurosurgery
. 2001 Apr;
48(4):810-6; discussion 816-7.
PMID: 11322441
Objective: To demonstrate that the shape of the configuration of fiducial points is an important factor governing target registration error (TRE) in point-based, rigid registration. Methods: We consider two clinical...
8.
Edwards P, King A, Maurer Jr C, de Cunha D, Hawkes D, Hill D, et al.
IEEE Trans Med Imaging
. 2001 Feb;
19(11):1082-93.
PMID: 11204846
The problem of providing surgical navigation using image overlays on the operative scene can be split into four main tasks--calibration of the optical system; registration of preoperative images to the...
9.
Hill D, Smith A, Simmons A, Maurer Jr C, Cox T, Elwes R, et al.
J Neurosurg
. 2000 Aug;
93(2):214-23.
PMID: 10930006
Object: Several authors have recently reported studies in which they aim to validate functional magnetic resonance (fMR) imaging against the accepted gold standard of invasive electrophysiological monitoring. The authors have...
10.
King A, Edwards P, Maurer Jr C, de Cunha D, Hawkes D, Hill D, et al.
Stereotact Funct Neurosurg
. 2000 Jun;
72(2-4):107-11.
PMID: 10853060
We present a system for surgical navigation using stereo overlays in the operating microscope aligned to the operative scene. This augmented reality system provides 3D information about nearby structures and...