» Authors » C Baldock

C Baldock

Explore the profile of C Baldock including associated specialties, affiliations and a list of published articles. Areas
Snapshot
Articles 71
Citations 1046
Followers 0
Related Specialties
Top 10 Co-Authors
Published In
Affiliations
Soon will be listed here.
Recent Articles
1.
Davies J, Izewska J, Meriaty H, Baldock C
Australas Phys Eng Sci Med . 2013 Feb; 36(1):55-8. PMID: 23400688
For over 30 years, the International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) have jointly monitored activities of secondary standard dosimetry laboratories (SSDLs) through postal dose audits...
2.
Baldock C, De Deene Y, Doran S, Ibbott G, Jirasek A, Lepage M, et al.
Phys Med Biol . 2010 Feb; 55(5):R1-63. PMID: 20150687
Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record...
3.
Vial P, Hunt P, Greer P, Oliver L, Baldock C
Australas Phys Eng Sci Med . 2008 Oct; 31(3):216-22. PMID: 18946980
This paper describes a software tool developed for research into the use of an electronic portal imaging device (EPID) to verify dose for intensity modulated radiation therapy (IMRT) beams. A...
4.
Brown S, Venning A, De Deene Y, Vial P, Oliver L, Adamovics J, et al.
Appl Radiat Isot . 2008 Aug; 66(12):1970-4. PMID: 18693028
The radiological properties of the PRESAGE and PAGAT polymer dosimeters have been investigated and their water equivalence determined for use in radiotherapy dosimetry. The radiological water equivalence of each of...
5.
Hill B, Venning A, Baldock C
Phys Med . 2008 Feb; 24(3):149-58. PMID: 18289906
Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to...
6.
Seneviratne M, Reinhard M, Baldock C
Phys Med Biol . 2007 Aug; 52(13):3837-46. PMID: 17664580
The low energy model of the GEANT4 Monte Carlo toolkit was used to simulate the energy response of a T.P.A. Mk-II ionization chamber under a variety of different conditions. The...
7.
Davies J, Enari K, Baldock C
Appl Radiat Isot . 2007 Jan; 65(5):517-8. PMID: 17258464
The reference air kerma rates of a set of individual (125)I seeds were calculated from current measurements of a calibrated re-entrant ionisation chamber. Single seeds were distributed to seven Australian...
8.
Dyksterhuis L, Baldock C, Lammie D, Wess T, Weiss A
Matrix Biol . 2006 Nov; 26(2):125-35. PMID: 17129717
The central region of tropoelastin including domains 19-25 of human tropoelastin forms a hot-spot for contacts during the inter-molecular association of tropoelastin by coacervation [Wise, S.G., Mithieux, S.M., Raftery, M.J....
9.
Robinson P, Arteaga-Solis E, Baldock C, Collod-Beroud G, Booms P, De Paepe A, et al.
J Med Genet . 2006 Mar; 43(10):769-87. PMID: 16571647
Marfan syndrome (MFS), a relatively common autosomal dominant hereditary disorder of connective tissue with prominent manifestations in the skeletal, ocular, and cardiovascular systems, is caused by mutations in the gene...
10.
Mo L, Reinhard M, Davies J, Alexiev D, Baldock C
Appl Radiat Isot . 2005 Nov; 64(4):485-9. PMID: 16293417
Primary standardisation was performed on a solution of (18)F using the 4pibeta-gamma coincidence counting efficiency-tracing extrapolation method with (60)Co used as a tracer nuclide. The result was used to calibrate...