» Articles » PMID: 9882014

Evaluation of a New Procedure for the Flow Cytometric Analysis of in Vitro, Chemically Induced Micronuclei in V79 Cells

Overview
Date 1999 Jan 9
PMID 9882014
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Measurement of the frequency of micronuclei induced in cells by ionizing radiation or by chemical treatment is widely used to analyze cytogenetic damage. The microscopic scoring of micronuclei is a tedious and time-consuming procedure. Therefore, attempts have been made to automate micronuclei scoring by means of image analysis or flow cytometry. A new procedure for the flow cytometric analysis of chemically induced micronuclei in V79 Chinese hamster cells has been established in our laboratory. Debris was separated from micronuclei by means of a new gating procedure using area and width fluorescence of the stained suspension of micronuclei and nuclei. In order to test the sensitivity and specificity of this improved method of flow cytometric analysis, five well-known mutagenic compounds were tested. With the new technique, the frequency of micronuclei measured and analyzed corresponded well with results obtained by conventional microscopy. In addition, a large series of negative compounds, and weak, middle, and strong micronuclei inducers, were tested in order to establish criteria for discrimination between genotoxic and nongenotoxic compounds by flow cytometry. This new procedure for flow cytometric detection of micronuclei represents a quick, reliable, and relatively simple method for in vitro micronucleus testing.

Citing Articles

Potentials of cytokinesis blocked micronucleus assay in radiation triage and biological dosimetry.

Tamizh Selvan G, Venkatachalam P J Genet Eng Biotechnol. 2024; 22(4):100409.

PMID: 39674629 PMC: 11381789. DOI: 10.1016/j.jgeb.2024.100409.


Suitability of the In Vitro Cytokinesis-Block Micronucleus Test for Genotoxicity Assessment of TiO Nanoparticles on SH-SY5Y Cells.

Fernandez-Bertolez N, Brandao F, Costa C, Pasaro E, Teixeira J, Laffon B Int J Mol Sci. 2021; 22(16).

PMID: 34445265 PMC: 8395234. DOI: 10.3390/ijms22168558.


Automation of the in vitro micronucleus assay using the Imagestream imaging flow cytometer.

Rodrigues M Cytometry A. 2018; 93(7):706-726.

PMID: 30118149 PMC: 6174940. DOI: 10.1002/cyto.a.23493.


In vitro micronucleus assay scored by flow cytometry provides a comprehensive evaluation of cytogenetic damage and cytotoxicity.

Bryce S, Bemis J, Avlasevich S, Dertinger S Mutat Res. 2007; 630(1-2):78-91.

PMID: 17434794 PMC: 1950716. DOI: 10.1016/j.mrgentox.2007.03.002.