» Articles » PMID: 9796892

Quantitative Evaluation of a Comprehensive Motion, Resolution, and Attenuation Correction Program: Initial Experience

Overview
Journal J Nucl Cardiol
Date 1998 Oct 31
PMID 9796892
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Tomographic myocardial imaging is widely used in the diagnosis and evaluation of patients with coronary artery disease. However, its specificity remains suboptimal because of attenuation, resolution, and motion artifacts. The purpose of this study was to optimize and assess the value of attenuation, blur, and motion correction of myocardial single photon emission computed tomographic data.

Methods And Results: Forty-seven studies were selected for analysis to provide 3 patient groups. Group A consisted of 18 patients with a low likelihood of coronary artery disease who were used to construct a quantitative normal database and assess changes in the normal bull's-eye produced by filtering and by attenuation correction. Group B consisted of 13 patients with a high probability of normal results, and group C consisted of 16 patients with coronary artery disease defined on angiography. The effects of attenuation correction, especially in conjunction with RESTORE (a depth-dependent deblurring filter), have been quantitated. Analysis indicates a trend to improved sensitivity and specificity for detecting individual vessel disease in this retrospective study. The motion correction program was successfully applied to 93% of patients but detected significant motion requiring correction in only 11 (24%) patients.

Conclusion: This preliminary retrospective study indicates a potential for improved myocardial single photon emission computed tomography imaging with the use of attenuation and motion correction together with a restorative deblurring filter. Confirmation by a multicenter study and larger patient numbers remain necessary to assess fully the prospective value of the technique.

Citing Articles

Use of MRI to assess the prediction of heart motion with gross body motion in myocardial perfusion imaging by stereotracking of markers on the body surface.

King M, Dey J, Johnson K, Dasari P, Mukherjee J, McNamara J Med Phys. 2013; 40(11):112504.

PMID: 24320463 PMC: 3815050. DOI: 10.1118/1.4824693.


Review: comparison of PET rubidium-82 with conventional SPECT myocardial perfusion imaging.

Ghotbi A, Kjaer A, Hasbak P Clin Physiol Funct Imaging. 2013; 34(3):163-70.

PMID: 24028171 PMC: 4204510. DOI: 10.1111/cpf.12083.


Present and future of clinical cardiovascular PET imaging in Europe--a position statement by the European Council of Nuclear Cardiology (ECNC).

Le Guludec D, Lautamaki R, Knuuti J, Bax J, Bengel F Eur J Nucl Med Mol Imaging. 2008; 35(9):1709-24.

PMID: 18581113 DOI: 10.1007/s00259-008-0859-1.


EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J Eur J Nucl Med Mol Imaging. 2005; 32(7):855-97.

PMID: 15909197 DOI: 10.1007/s00259-005-1779-y.


Gated SPECT assessment of left ventricular function is sensitive to small patient motions and to low rates of triggering errors: a comparison with equilibrium radionuclide angiography.

Djaballah W, Muller M, Bertrand A, Marie P, Chalon B, Djaballah K J Nucl Cardiol. 2005; 12(1):78-85.

PMID: 15682368 DOI: 10.1016/j.nuclcard.2004.08.008.


References
1.
Jain A, Murray D . Detection of myocardial ischemia. Curr Probl Cardiol. 1995; 20(11):773-824. DOI: 10.1016/s0146-2806(06)80019-8. View

2.
Tan P, Bailey D, Meikle S, Eberl S, Fulton R, Hutton B . A scanning line source for simultaneous emission and transmission measurements in SPECT. J Nucl Med. 1993; 34(10):1752-60. View

3.
Arnese M, Cornel J, Salustri A, Maat A, Elhendy A, Reijs A . Prediction of improvement of regional left ventricular function after surgical revascularization. A comparison of low-dose dobutamine echocardiography with 201Tl single-photon emission computed tomography. Circulation. 1995; 91(11):2748-52. DOI: 10.1161/01.cir.91.11.2748. View

4.
Prvulovich E, Lonn A, Bomanji J, Jarritt P, Ell P . Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease. Eur J Nucl Med. 1997; 24(3):266-75. DOI: 10.1007/BF01728762. View

5.
King M, Tsui B, Pan T, Glick S, Soares E . Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms. J Nucl Cardiol. 1996; 3(1):55-64. DOI: 10.1016/s1071-3581(96)90024-0. View