» Articles » PMID: 9776271

Generation of Myocardial Factor Images Directly from the Dynamic Oxygen-15-water Scan Without Use of an Oxygen-15-carbon Monoxide Blood-pool Scan

Overview
Journal J Nucl Med
Specialty Nuclear Medicine
Date 1998 Oct 17
PMID 9776271
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Unlabelled: The measurement of regional myocardial blood flow (MBF) with H2(15)O and PET requires an additional C15O blood-pool scan for the purpose of region of interest (ROI) definition. This additional scan results in a substantially increased radiation dose, study duration and risk of movement artifacts. Therefore, a method was developed to generate myocardial factor images directly from the dynamic H2(15)O study without the need for a C15O scan.

Methods: The factor sinograms were generated by means of linear dimension reduction of the dynamic sinograms, where the required variate and covariate factors (myocardial and blood time-activity curves) were modeled from the lung time-activity curve. The factor images were generated by iterative reconstruction.

Results: No significant difference was found between MBF values from ROIs drawn on the traditional images (using the C15O scan) and those drawn on the factor images.

Conclusion: It is possible to generate myocardial images directly from the dynamic H2(15)O study, so that the C15O scan can be omitted from MBF studies. The proposed method is robust and results in nearly optimal signal-to-noise ratios in the factor images.

Citing Articles

Pioglitazone Improves Left Ventricular Diastolic Function in Subjects With Diabetes.

Clarke G, Solis-Herrera C, Molina-Wilkins M, Martinez S, Merovci A, Cersosimo E Diabetes Care. 2017; 40(11):1530-1536.

PMID: 28847910 PMC: 5652586. DOI: 10.2337/dc17-0078.


Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM).

Sciagra R, Passeri A, Bucerius J, Verberne H, Slart R, Lindner O Eur J Nucl Med Mol Imaging. 2016; 43(8):1530-45.

PMID: 26846913 DOI: 10.1007/s00259-016-3317-5.


Validation of pixel-wise parametric mapping of myocardial blood flow with ¹³NH₃ PET in patients with hypertrophic cardiomyopathy.

Sciagra R, Passeri A, Cipollini F, Castagnoli H, Olivotto I, Burger C Eur J Nucl Med Mol Imaging. 2015; 42(10):1581-8.

PMID: 26121929 DOI: 10.1007/s00259-015-3101-y.


PET tracers and techniques for measuring myocardial blood flow in patients with coronary artery disease.

Hsu B J Biomed Res. 2013; 27(6):452-9.

PMID: 24285943 PMC: 3841470. DOI: 10.7555/JBR.27.20130136.


Use of a beta microprobe system to measure arterial input function in PET via an arteriovenous shunt in rats.

Warnock G, Bahri M, Goblet D, Giacomelli F, Lemaire C, Aerts J EJNMMI Res. 2012; 1(1):13.

PMID: 22214227 PMC: 3250971. DOI: 10.1186/2191-219X-1-13.